LPOD C-, X-, or Ku-Band Outdoor Amplifier / Block Up Converter (BUC) MN-LPOD
Serial-based Remote Product Management Revision 10
5–35
Parameter Type
(Instruction
Code and
for Command
or Response
Description of Arguments
(Note that all arguments are printable ASCII characters)
Command
(Target to
(Instruction
Code and
Response to Query
(Target to
Controller)
Sets or returns the real-time clock time, from midnight, in the form hhmmss, where:
hh = hours, from 00 to 23
mm = minutes, from 00 to 59
ss = seconds, from 00 to 59
Example (time = 23 hours, 12 minutes and 59 seconds since midnight): <1/TIM=231259’cr’
>0001/TIM=’cr’’lf’
TIM?
TIM *
(See Description of
Arguments)
Returns the temperatures of the Heatsink in the form of sxxxx, where:
s = sign (+) or (-)
xxxx = temperature.
Example: <1/TMP=+26.0
(See Description of
Arguments)
of Unread Stored
Alarms
E
Returns the number of stored alarms that remain unread in the alarm log, in the form xx. A maximum of 255
events may be stored in the alarm log. Numbers over 99 are reported as 99.
Example reply: <1/TNA? ’cr’
>0001/TNA=14’cr’’lf’
(See Description of
Arguments)
of Unread Stored
Events
numerical
Returns the number of stored events that remain unread in the events logs, in the form xx.
Example: <1/TNE? ’cr’
(See Description of
Arguments)
Enable
numerical
Sets or returns the Time Protocol setting in the form x, where:
0 = Time protocol disabled
1 = Time protocol enabled
Example (Time protocol enabled): <1/TPE=1’cr’
TPE?
(See Description of
Arguments)
Server
alpha-numeric
Sets or returns the Time Server IP address for the Unit Tx Ethernet management port, in the form
xxx.xxx.xxx.xxx
Default value: 255.255.255.255
Example: <1/TPS=192.168.001.005
TPS?
xx.xxx.xxx.xxx.yy
(See Description of
Arguments)