LPOD C-, X-, or Ku-Band Outdoor Amplifier / Block Up Converter (BUC) MN-LPOD
Serial-based Remote Product Management Revision 10
5–17
Parameter Type
(Instruction
Code and
for Command
or Response
Description of Arguments
(Note that all arguments are printable ASCII characters)
Command
(Target to
(Instruction
Code and
Response to Query
(Target to
Controller)
Time-Clock) Date
E
Sets or returns the real-time clock date in the form mmddyy, where;
dd = day of the month, from 01 to 31,
mm = month of the year, from 01 to 12
yy = year, from 00 to 96 (2000 to 2096)
Example (date = April 24, 2003):
<1/DAT=042403’cr’
DAT?
DAT*
(See Description of
Arguments)
Time-Clock) Date
Sets or returns the real-time clock date in the form ddmmyy, where;
dd = day of the month, from 01 and 31,
mm = month of the year, from 01 to 12
yy = year, from 00 to 99 (2000 to 2099)
Example (date = April 24, 2003):
<1/DAY=240403’cr’
>0001/DAY=’cr’’lf’
DAY?
DAY*
Description of
Arguments)
Averaging
Enables or Disables averaging of statistics data at a rate of once per second for 10 seconds, in the form x,
where:
0 = Disable (default value)(see Note)
1 = Enable
Note: If Disabled, burst values will be logged instead of averaged values.
Example: <1/ESA=0’cr’
>0001/ESA=’cr’’lf’
ESA?
ESA*
(See Description of
Arguments)
Logging
Sets or returns the statistics logging function in the form x, where:
0 = Disable (default value)
1 = Enable
Example: <1/ESL=1’cr’
ESL?
ESL*
(See Description of
Arguments)