LPOD C-, X-, or Ku-Band Outdoor Amplifier / Block Up Converter (BUC) MN-LPOD
Serial-based Remote Product Management Revision 10
5–30
Parameter Type
(Instruction
Code and
for Command
or Response
Description of Arguments
(Note that all arguments are printable ASCII characters)
Command
(Target to
(Instruction
Code and
Response to Query
(Target to
Controller)
Unread Stored
Events
Returns the oldest 5 Stored Events which have not yet been read over the remote control in the format {CR}Sub-body{CR}Sub-
body{CR}Sub-body{CR} Sub-body{CR}Sub-body, where:
Sub-body= ABCCddmmyyhhmmss:
A being the fault/clear indicator.
F=Fault
C=Clear
I=Info
B being the fault type where:
1=Unit
2=RF
3=Log
CC is Fault Code numbers, as in RAS? or Info Code, which is:
0=Power Off
1=Power On
2=Log Cleared
3=Global Config Change
4=Redundancy Config Change
RAS fault codes map as follows:
1) P24V1
2) P24V2
3) LNBVT
4) P13VT
5) A10V1
6) A10V2
7) 10VPS
8) P5V8T
9) P2V5T
10) P1V2T
11) N5V8T
12) P7V8T
13) FANR1
14) FANR2
15) ATEMP
16) SHTDN
17) IICST
18) FWPWR
19) CHKSM
20) FPGAD
21) BUCLD
22) REFLD
23) LNBCS
24) SWITC
If there are less than 5 events to be retrieved, the remaining positions are padded with zeros. If there are no new events, the
response is RNE*. A Global Config Change is defined as any time a command is successfully executed. A query does not set
mmyyhhmmss{CR}A
BCCddmmyyhhmms
s{CR}ABCCddmmyy
hhmmss{CR}ABCCd
dmmyyhhmmss{CR}
ABCCddmmyyhhm
mss
(See Description of
Arguments)