LPOD C-, X-, or Ku-Band Outdoor Amplifier / Block Up Converter (BUC) MN-LPOD
Serial-based Remote Product Management Revision 10
5–28
Parameter Type
(Instruction
Code and
for Command
or Response
Description of Arguments
(Note that all arguments are printable ASCII characters)
Command
(Target to
(Instruction
Code and
Response to Query
(Target to
Controller)
Oscillator Tuning
Sets or returns the reference oscillator tuning voltage adjustment by sending a DAC value in the form xxx,
where:
xxx = is a numeric value from 0 to 255.
Default value: 087
Note: This command sets the DAC value, but the actual Reference Oscillator tuning voltage can be monitored
using the RMS command.
Example: <1/REF=087’cr’
>0001/REF=’cr’’lf’
REF?
REF*
(See Description of
Arguments)
Equipment Type
E
Returns a string indicating the Model Number and the version of the M&C firmware installed in the unit.
Example: <1/RET?’cr’
>0001/RET=PS2053-5967-C REF BUC VER: 1.5.2’cr’’lf’
(See Description of
Arguments)
Current Status
depending on
the number of
FETs installed
in the RF
amplifier
Returns all FET currents in the form xx.x when the value is >1 Amp, or xxx when the value is < 1 AMP
Example: <1/RFS? ’cr’
>0001/RFS=’cr’
Q01=.xxx’cr’
Q02=.xxx’cr’
Q03=xx.x’cr’
Q04=xx.x’cr’
Q05=xx.x’cr’
Q06=xx.x’cr’
Q07=xx.x’cr’
Q08=xx.x’cr’
Q09=xx.x’cr’
Q10=xx.x’cr’
Q11=xx.x’cr’
Q12=xx.x’cr’
Q13=xx.x’cr’
Q14=xx.x’cr’
Q15=xx.x’cr’
(See Description of
Arguments)