LPOD C-, X-, or Ku-Band Outdoor Amplifier / Block Up Converter (BUC) MN-LPOD
Serial-based Remote Product Management Revision 10
5–14
Parameter Type
(Instruction
Code and
for Command
or Response
Description of Arguments
(Note that all arguments are printable ASCII characters)
Command
(Target to
(Instruction
Code and
Response to Query
(Target to
Controller)
Configuration
Status
This is the concise version of the RCS query. Returns the configuration status of the unit, in the form
aa.aa;b;c;d;e;ff.ff;g;hhh, where:
aa.aa = attenuation in dB (ATT)
b = RF power amplifier state, 0 = Off, 1 = On (AMP)
c = mute state, 0 = un-muted, 1 = muted (MUT)
d = online status (ONL)
e = redundancy state and mode (ESW)
ff.ff = Attenuator offset in dB (AOF)
g = auto fault recovery mode (AFR)
hhh = External reference status, N/A = no external reference, 05M for 5 MHz, and 10M for a 10 MHz (See
Note)
Note: hhh will always be N/A if the internal reference oscillator option is not installed.
Example: CCS=aa.aa;b;c;d;e;ff.ff;g;hhh; ’cr’’lf’
ff.ff;g;hhh
(See Description of
Arguments)
FET Current
Status
depending on
number of
FETs installed
in the amplifier
This is the concise version of the RFS query. Returns the RF Power FET Current status.
Example: CFS=xxx,xxx,x.x,x.x,……….,x.x,
(See description of
RFS. Note that each
argument is
separated by a
comma.)
Identification
Sets or returns a 48-byte user-defined string that identifies or names the unit or station. The CID is entered as
one line, but it reads back from the unit as two 24-byte lines of data.
Default value: ------------------------
Examples:
<1/CID= Station #001--SSPA #01--’cr’
>0001/CID=
<1/CID?’cr’
>0001/CID=’cr’
Station #001’cr’
CID?
CID*
(See Description of
Arguments)