LPOD C-, X-, or Ku-Band Outdoor Amplifier / Block Up Converter (BUC) MN-LPOD
Serial-based Remote Product Management Revision 10
5–22
Parameter Type
(Instruction
Code and
for Command
or Response
Description of Arguments
(Note that all arguments are printable ASCII characters)
Command
(Target to
(Instruction
Code and
Response to Query
(Target to
Controller)
State
Sets or returns Local or Remote state for Indoor SSPA (always in remote mode for Outdoor SSPA) in the form x,
where x=0, 1, 2, or 3::
0 = Local
1=Serial
2=Ethernet
3=Serial+Ethernet (default value)
Note: The user will always have query access in any mode. The LRS command is also available in all modes as
a means of acquiring control. The intent of this command is to limit changes from being made on multiple
interfaces at the same time. Units without a front panel will treat an entry of 0 as reserved, and will refuse the
command by returning a mode error. The web page GUI will refuse connections unless LRS is set to enable
Ethernet remote control.
Example: <1/LRS=3’cr’
>0001/LRS=’cr’’lf’
LRS?
(See Description of
Arguments)
Returns the MAC address of the unit, in hexadecimal format xx-xx-xx-xx-xx-xx
Example: <1/MAC?’cr’
>0001/MAC=00-06-B0-00-D2-A7’cr’’lf’
xx-xx
(See Description of
Arguments)
Comentários a estes Manuais