Comtech EF Data DMD-2050E Especificações Página 1

Consulte online ou descarregue Especificações para Redes Comtech EF Data DMD-2050E. Comtech EF Data DMD-2050E Product specifications Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir

Resumo do Conteúdo

Página 1 - DMD-2050E

MN-DMD2050E Revision 2 Comtech EF Data is an AS9100 Rev B / ISO9001:2000 Registered Company DMD-2050E Universal Satellite Modem Installa

Página 2

BLANK PAGE

Página 3

DMD2050E Universal Satellite Modem Theory of Operation MN-DMD2050E Revision 2 3–58 Table 3-4. Reed-Solomon Codes Type of Service Data Rate (Kbps)

Página 4

DMD2050E Universal Satellite Modem Theory of Operation MN-DMD2050E Revision 2 3–59 rate through the modem. The overhead channel is recovered at t

Página 5

DMD2050E Universal Satellite Modem Theory of Operation MN-DMD2050E Revision 2 3–60 Kbps Standard IBS Baud Rate Example Kbps Enhanced Mode Baud R

Página 6

DMD2050E Universal Satellite Modem Theory of Operation MN-DMD2050E Revision 2 3–61 The ratio of the Through Terrestrial Data Channel Rate to the

Página 7

DMD2050E Universal Satellite Modem Theory of Operation MN-DMD2050E Revision 2 3–62 The user can connect whichever systems on the earth stations th

Página 8

DMD2050E Universal Satellite Modem Theory of Operation MN-DMD2050E Revision 2 3–63 The number of user data slots and control words per frame is se

Página 9

DMD2050E Universal Satellite Modem Theory of Operation MN-DMD2050E Revision 2 3–64 3.19.2 Aggregate Data Rate The aggregate data rate equals the

Página 10 - BLANK PAGE

DMD2050E Universal Satellite Modem Theory of Operation MN-DMD2050E Revision 2 3–65 3.19.3 Overhead Rate Comparison The SCC Overhead Ratio varies

Página 11 - Table of Contents

DMD2050E Universal Satellite Modem Theory of Operation MN-DMD2050E Revision 2 3–66 3.19.4 Actual Overhead Rate Calculation The following is the a

Página 12

DMD2050E Universal Satellite Modem Theory of Operation MN-DMD2050E Revision 2 3–67 3.20 SCC OVERHEAD CHANNEL SETUP 1. Set the Framing Mode (loca

Página 13

DMD-2050E Universal Satellite Modem Revision 2 Table of Contents MN-DMD2050E iii Table of Contents PREFACE ...

Página 14

DMD2050E Universal Satellite Modem Theory of Operation MN-DMD2050E Revision 2 3–68 9. The physical connection to the DMD2050E for the overhead ch

Página 15 - vii

DMD2050E Universal Satellite Modem Theory of Operation MN-DMD2050E Revision 2 3–69 3.21 Locating the DMD2050E ID Code Operational Procedure Uniqu

Página 16 - viii

DMD2050E Universal Satellite Modem Theory of Operation MN-DMD2050E Revision 2 3–70 BLANK PAGE

Página 17

MN-DMD2050E Revision 2 4–1 Chapter 4. User Interfaces 4.1 User Interfaces The DMD2050E has three interfaces available for typical operations: •

Página 18

DMD2050E Universal Satellite Modem User Interfaces MN-DMD2050E Revision 2 4–2 Table 4-1. Front Panel Functions Area Function VFD Shows operating

Página 19

DMD2050E Universal Satellite Modem User Interfaces MN-DMD2050E Revision 2 4–3 Parameter Type 0 – 9     Clear &  Clear &  IP Address

Página 20 - xii

DMD2050E Universal Satellite Modem User Interfaces MN-DMD2050E Revision 2 4–4 4.3 Parameter Setup 4.3.1 Select a Parameter Use the arrow keys to

Página 21 - xiii

DMD2050E Universal Satellite Modem User Interfaces MN-DMD2050E Revision 2 4–5 4.4.1 MODULATOR Main Menu and Parameters 4.4.1.1 NETWORK SPEC (men

Página 22 - xiv

DMD2050E Universal Satellite Modem User Interfaces MN-DMD2050E Revision 2 4–6 4.4.1.2 STRAP CODE The STRAP CODE is another means for quickly sett

Página 23 - Figures

DMD2050E Universal Satellite Modem User Interfaces MN-DMD2050E Revision 2 4–7 DATA MENU Trellis (8PSK) {2/3} TPC (BPSK) {5/16, 21/44} ≤ 20Mbp

Página 24 - xvi

DMD-2050E Universal Satellite Modem Revision 2 Table of Contents MN-DMD2050E iv CHAPTER 2. INSTALLATION ...

Página 25 - PREFACE

DMD2050E Universal Satellite Modem User Interfaces MN-DMD2050E Revision 2 4–8 DATA MENU TERR FRAMING {NONE, 188, 204} DVB Only DATA POLARITY {I

Página 26 - Grounding

DMD2050E Universal Satellite Modem User Interfaces MN-DMD2050E Revision 2 4–9 4.4.1.5 REED-SOLOMON (menu) IMPORTANT When Reed-Solomon is select

Página 27 - Low Voltage Directive (LVD)

DMD2050E Universal Satellite Modem User Interfaces MN-DMD2050E Revision 2 4–10 4.4.1.7 LOCAL AUPC (menu) NOTE When modems are configured for Rad

Página 28 - CE Mark

DMD2050E Universal Satellite Modem User Interfaces MN-DMD2050E Revision 2 4–11 LOCAL AUPC MENU MINIMUM TX POWER {0 to -45 dB} Set the minimum Tran

Página 29 - Preface MN-DMD2050E

DMD2050E Universal Satellite Modem User Interfaces MN-DMD2050E Revision 2 4–12 LOCAL AUPC MENU TARGET Eb/No {4.0 to 16 dB} Set the desired Eb/No f

Página 30

DMD2050E Universal Satellite Modem User Interfaces MN-DMD2050E Revision 2 4–13 4.4.1.8 REMOTE AUPC (menu) NOTE Remote AUPC Menus are available o

Página 31 - Chapter 1. Introduction

DMD2050E Universal Satellite Modem User Interfaces MN-DMD2050E Revision 2 4–14 8PSK 2/3 {NOT SELECTED, SELECTED} Used to select the mod/code rate

Página 32 - 1.2.1 Features

DMD2050E Universal Satellite Modem User Interfaces MN-DMD2050E Revision 2 4–15 Closed Net All possible combinations are allowed. NOTE: DVB settin

Página 33 - 1.2.3 Bandwidth Compression

DMD2050E Universal Satellite Modem User Interfaces MN-DMD2050E Revision 2 4–16 IF MENU INPUT THRESHOLD (dBm) {-30 to –90} Sets the minimum carrie

Página 34 - 1.2.7 Physical Description

DMD2050E Universal Satellite Modem User Interfaces MN-DMD2050E Revision 2 4–17 DATA MENU SCRAMBLER SEL {NONE, V.35-IESS, V.35 CITT, V.35 EF, IBS w

Página 35

DMD-2050E Universal Satellite Modem Revision 2 Table of Contents MN-DMD2050E v 3.5.3.3 SCT: Serial Clock Transmit ...

Página 36

DMD2050E Universal Satellite Modem User Interfaces MN-DMD2050E Revision 2 4–18 4.4.2.6 CNC (menu) IMPORTANT When the Carrier-in-Carrier® option

Página 37 - Chapter 2. Installation

DMD2050E Universal Satellite Modem User Interfaces MN-DMD2050E Revision 2 4–19 4.4.3 INTERFACE Main Menu and Parameters 4.4.3.1 TX SETUP (menu)

Página 38 - 2.2 Installation Safety

DMD2050E Universal Satellite Modem User Interfaces MN-DMD2050E Revision 2 4–20 IMPORTANT When Ethernet Interface is selected or EBEM Network spe

Página 39 - 2.3.4 Electrical Power

DMD2050E Universal Satellite Modem User Interfaces MN-DMD2050E Revision 2 4–21 4.4.3.1.1 DROP & INSERT (menu) DROP & INSERT MENU DROP MOD

Página 40 - 2.3.5 Cables

DMD2050E Universal Satellite Modem User Interfaces MN-DMD2050E Revision 2 4–22 4.4.3.2 RX SETUP (menu) RX SETUP MENU CIRCUIT ID Enter the Rx Ci

Página 41 - 2.5.1 Initial Start Up

DMD2050E Universal Satellite Modem User Interfaces MN-DMD2050E Revision 2 4–23 4.4.3.2.1 DROP & INSERT (menu) INSERT MODE {NONE, T1-D4, T1-ES

Página 42

DMD2050E Universal Satellite Modem User Interfaces MN-DMD2050E Revision 2 4–24 4.4.3.3 GENERAL (menu) GENERAL MENU EXT FREQ (MHz) {Variable Throu

Página 43 - 3.1 DMD2050E Hardware

DMD2050E Universal Satellite Modem User Interfaces MN-DMD2050E Revision 2 4–25 MONITOR MENU CORRECTED BER The CBER display shows an estimated corr

Página 44

DMD2050E Universal Satellite Modem User Interfaces MN-DMD2050E Revision 2 4–26 NOTE Port status indicators are: Down: The link is down. Unreso

Página 45

DMD2050E Universal Satellite Modem User Interfaces MN-DMD2050E Revision 2 4–27 4.4.4.2 VOLTAGES (menu) VOLTAGES MENU TEMPERATURE Displays interna

Página 46

DMD-2050E Universal Satellite Modem Revision 2 Table of Contents MN-DMD2050E vi 3.11.12.4 Estimating PSD Ratio from Satmaster ...

Página 47 - 3.2.2 Baseband Processing

DMD2050E Universal Satellite Modem User Interfaces MN-DMD2050E Revision 2 4–28 4.4.5 ALARMS Main Menu and Parameters Alarm details are described

Página 48

DMD2050E Universal Satellite Modem User Interfaces MN-DMD2050E Revision 2 4–29 4.4.6.3 TERMINAL (menu) TYPE {VT-100, WYSE50, VIEWPOINT} Select t

Página 49

DMD2050E Universal Satellite Modem User Interfaces MN-DMD2050E Revision 2 4–30 TCP/IP MENU BOOTp SERVER {128 – 257, default is 206} Only used if

Página 50 - 3.2.6 Terminal Port

DMD2050E Universal Satellite Modem User Interfaces MN-DMD2050E Revision 2 4–31 4.4.6.6 SNMP (menu) A description of OID organization is provided

Página 51 - 3.2.9 Modem Monitor Status

DMD2050E Universal Satellite Modem User Interfaces MN-DMD2050E Revision 2 4–32 4.4.6.7 FTP (menu) PORT {XXXX} Select the desired port number.

Página 52 - 3.3 Internal Clock

DMD2050E Universal Satellite Modem User Interfaces MN-DMD2050E Revision 2 4–33 4.4.6.9 TRANSEC (menu) TRANSEC MENU IP ADDR MASK {XXX.XXX.XXX.XXX}

Página 53

DMD2050E Universal Satellite Modem User Interfaces MN-DMD2050E Revision 2 4–34 4.4.6.10.1 MAIN BOARD (menu) NOTE Only the applicable VCO adjustm

Página 54

DMD2050E Universal Satellite Modem User Interfaces MN-DMD2050E Revision 2 4–35 CNC BOARD (menu) Indicates the part number for the CNC Board. DEBU

Página 55 - 3.5.1 Clock Selection

DMD2050E Universal Satellite Modem User Interfaces MN-DMD2050E Revision 2 4–36 4.4.7 TEST Main Menu and Parameters TEST MENU TX TEST PATTERN {NON

Página 56 - 3.5.2 TX Clock Options

DMD2050E Universal Satellite Modem User Interfaces MN-DMD2050E Revision 2 4–37 TEST MENU IQ SAMPLING {ENABLE/DISABLE} Enables the I & Q patte

Página 57

DMD-2050E Universal Satellite Modem Revision 2 Table of Contents MN-DMD2050E vii 4.4 Front Panel Main Menus ...

Página 58 - 3.5.3.1 RX SAT Clock

DMD2050E Universal Satellite Modem User Interfaces MN-DMD2050E Revision 2 4–38 4.5 Terminal Mode Control The Terminal Mode Control lets you use a

Página 59 - Frequency 1 MHz to 20 MHz

DMD2050E Universal Satellite Modem User Interfaces MN-DMD2050E Revision 2 4–39 For numerical input, use the number keys to input the data. Press E

Página 60 - 3.6.3 HSSI Interface

DMD2050E Universal Satellite Modem User Interfaces MN-DMD2050E Revision 2 4–40 BLANK PAGE

Página 61

MN-DMD2050E Revision 2 5–1 Chapter 5. External Connections Figure 5-1. DMD2050E Universal Satellite Modem Front Panel Figure 5-2. DMD2050E Rear

Página 62 - 3.9 STANAG Turbo Coding

DMD2050E Universal Satellite Modem External Connections MN-DMD2050E Revision 2 5–2 5.1 Power Connectors, Ground and Switches The DMD2050E units h

Página 63 - 3.10.1.1 Key Agreement

DMD2050E Universal Satellite Modem External Connections MN-DMD2050E Revision 2 5–3 5.2 Front Panel Connections 5.2.1 Key Loader Interface Label

Página 64

DMD2050E Universal Satellite Modem External Connections MN-DMD2050E Revision 2 5–4 5.3 Rear Panel Connectors CAUTION Before you connect any cab

Página 65

DMD2050E Universal Satellite Modem External Connections MN-DMD2050E Revision 2 5–5 5.3.2 EXT REF (J10) Label Description Connector Type Input Lev

Página 66 - 3.10.1.2.1 Key Derivation

DMD2050E Universal Satellite Modem External Connections MN-DMD2050E Revision 2 5–6 5.3.4 ALARM (J15) Label Description Connector Type ALARM J15

Página 67

DMD2050E Universal Satellite Modem External Connections MN-DMD2050E Revision 2 5–7 5.3.4.1 IBS Network Alarms Configuration IBS Prompt Alarms IBS

Página 68

DMD-2050E Universal Satellite Modem Revision 2 Table of Contents MN-DMD2050E viii 4.5 Terminal Mode Control...

Página 69

DMD2050E Universal Satellite Modem External Connections MN-DMD2050E Revision 2 5–8 5.3.6 ASYNC (J17) Label Description Connector Type ASYNC J17

Página 70

DMD2050E Universal Satellite Modem External Connections MN-DMD2050E Revision 2 5–9 5.3.8 MIL-188-114A (J19) Label Description Connector Type MI

Página 71 - DMD2050E CnC Module

DMD2050E Universal Satellite Modem External Connections MN-DMD2050E Revision 2 5–10 5.3.9 Monitor and Control Connectors J20, J21 Label Descript

Página 72

MN-DMD2050E Revision 2 6–1 Chapter 6. Maintenance and Troubleshooting 6.1 Periodic Maintenance 6.1.1 Battery Replacement WARNING: DANGER OF EX

Página 73

DMD2050E Univeral Satellite Modem Maintenance and Troubleshooting MN-DMD2050E Revision 2 6–2 6.2 Troubleshooting 6.2.1 Basic Troubleshooting Pro

Página 74

DMD2050E Univeral Satellite Modem Maintenance and Troubleshooting MN-DMD2050E Revision 2 6–3 6.3 Alarms 6.3.1 Major Transmit Alarms Alarm Desc

Página 75

DMD2050E Univeral Satellite Modem Maintenance and Troubleshooting MN-DMD2050E Revision 2 6–4 Alarm Description Status INPUT LVL THRESH Indicates t

Página 76

DMD2050E Univeral Satellite Modem Maintenance and Troubleshooting MN-DMD2050E Revision 2 6–5 Alarm Description Status TPC CONFLICT CHK Indicates t

Página 77 - 3.11.6 Margin Requirements

DMD2050E Univeral Satellite Modem Maintenance and Troubleshooting MN-DMD2050E Revision 2 6–6 Alarm Description Status RX AGC LEVEL Indicates Rx le

Página 78

DMD2050E Univeral Satellite Modem Maintenance and Troubleshooting MN-DMD2050E Revision 2 6–7 Alarm Description Status +3.3V SUPPLY Shows the measu

Página 79

DMD-2050E Universal Satellite Modem Revision 2 Table of Contents MN-DMD2050E ix 6.4 Alarm Masks ...

Página 80

DMD2050E Univeral Satellite Modem Maintenance and Troubleshooting MN-DMD2050E Revision 2 6–8 6.4 Alarm Masks The DMD2050E self-monitors and isola

Página 81

DMD2050E Univeral Satellite Modem Maintenance and Troubleshooting MN-DMD2050E Revision 2 6–9 Alarms are grouped into transmit and receive alarms.

Página 82

DMD2050E Univeral Satellite Modem Maintenance and Troubleshooting MN-DMD2050E Revision 2 6–10 RX MAJOR (menu) {Pass/Fail} RX MINOR (menu) {Pass/Fa

Página 83

DMD2050E Univeral Satellite Modem Maintenance and Troubleshooting MN-DMD2050E Revision 2 6–11 NOTE These alarms show the status of the alarms RE

Página 84

DMD2050E Univeral Satellite Modem Maintenance and Troubleshooting MN-DMD2050E Revision 2 6–12 6.5 IBS Alarms and Actions Figure 6-1 and Table 6-1

Página 85

MN-DMD2050E Revision 2 7–1 Chapter 7. Technical Specifications 7.1 Modulator Modulator Specifications Modulation BPSK, QPSK, OQPSK, 8-PSK, 8-QA

Página 86

DMD2050E Universal Satellite Modem Technical Specifications MN-DMD2050E Revision 2 7–2 Modulator Specifications Turbo (16-QAM) {3/4, 7/8} ≤ 20Mb

Página 87

DMD2050E Universal Satellite Modem Technical Specifications MN-DMD2050E Revision 2 7–3 Demodulator Specifications Turbo (OQPSK/QPSK) {1/2, 3/4, 7

Página 88

DMD2050E Universal Satellite Modem Technical Specifications MN-DMD2050E Revision 2 7–4 7.5 Terrestrial Interfaces MIL-188-114A, HSSI GiGE 10/100/

Página 89

DMD2050E Universal Satellite Modem Technical Specifications MN-DMD2050E Revision 2 7–5 7.11 Data Rate Limits 7.11.1 Non-DVB Non-DVB Data Rate Li

Página 90

DMD-2050E Universal Satellite Modem Revision 2 Table of Contents MN-DMD2050E x 7.12.14 B/O/QPSK BER Performance (LDPC) ...

Página 91 - 3.11.15 Glossary

DMD2050E Universal Satellite Modem Technical Specifications MN-DMD2050E Revision 2 7–6 Non-DVB Data Rate Limits Modulation Code Rate Min Data Rate

Página 92

DMD2050E Universal Satellite Modem Technical Specifications MN-DMD2050E Revision 2 7–7 7.11.2 DVB DVB Data Rate Limits Modulation Code Rate DVB M

Página 93

DMD2050E Universal Satellite Modem Technical Specifications MN-DMD2050E Revision 2 7–8 DVB Data Rate Limits Modulation Code Rate DVB Mode Min Data

Página 94 - 3.12.1 LDPC versus TPC

DMD2050E Universal Satellite Modem Technical Specifications MN-DMD2050E Revision 2 7–9 7.12 BER Specifications 7.12.1 BER Performance (Viterbi)

Página 95

DMD2050E Universal Satellite Modem Technical Specifications MN-DMD2050E Revision 2 7–10 7.12.2 BER Performance (Sequential) Figure 7-2. DMD2050E

Página 96

DMD2050E Universal Satellite Modem Technical Specifications MN-DMD2050E Revision 2 7–11 7.12.3 BER Performance (Viterbi with Reed-Solomon) Figur

Página 97

DMD2050E Universal Satellite Modem Technical Specifications MN-DMD2050E Revision 2 7–12 7.12.4 BER Performance (Turbo) Figure 7-4. DMD2050E B/O

Página 98 - 3.13 Reed-Solomon Codec

DMD2050E Universal Satellite Modem Technical Specifications MN-DMD2050E Revision 2 7–13 7.12.5 BER Performance (8PSK Trellis) Figure 7-5. DMD20

Página 99 - 3.13.3 Interleaving

DMD2050E Universal Satellite Modem Technical Specifications MN-DMD2050E Revision 2 7–14 7.12.6 BER Performance (8PSK Turbo) Figure 7-6. DMD2050E

Página 100 - Communications)

DMD2050E Universal Satellite Modem Technical Specifications MN-DMD2050E Revision 2 7–15 7.12.7 BER Performance (16QAM Viterbi) Figure 7-7. DMD20

Página 101

DMD-2050E Universal Satellite Modem Revision 2 Table of Contents MN-DMD2050E xi D.2.2 IP Address ...

Página 102 - 3.16 Standard IBS Mode

DMD2050E Universal Satellite Modem Technical Specifications MN-DMD2050E Revision 2 7–16 7.12.8 BER Performance (16QAM Viterbi with Reed-Solomon)

Página 103 - 3.18 ESC Backward Alarms

DMD2050E Universal Satellite Modem Technical Specifications MN-DMD2050E Revision 2 7–17 7.12.9 BER Performance (16QAM Turbo) Figure 7-9. DMD2050

Página 104 - See also:

DMD2050E Universal Satellite Modem Technical Specifications MN-DMD2050E Revision 2 7–18 7.12.10 BER Performance (OQPSK Turbo) Figure 7-10. DMD2

Página 105

DMD2050E Universal Satellite Modem Technical Specifications MN-DMD2050E Revision 2 7–19 7.12.11 BER Performance (BPSK Turbo) Figure 7-11. DMD20

Página 106 - 3.19.2 Aggregate Data Rate

DMD2050E Universal Satellite Modem Technical Specifications MN-DMD2050E Revision 2 7–20 7.12.12 BER Performance (8PSK Turbo) Figure 7-12. DMD20

Página 107

DMD2050E Universal Satellite Modem Technical Specifications MN-DMD2050E Revision 2 7–21 7.12.13 BER Performance (16QAM Turbo) Figure 7-13. DMD2

Página 108 - (less than In-Band Rate)

DMD2050E Universal Satellite Modem Technical Specifications MN-DMD2050E Revision 2 7–22 7.12.14 B/O/QPSK BER Performance (LDPC) Figure 7-14. DM

Página 109

DMD2050E Universal Satellite Modem Technical Specifications MN-DMD2050E Revision 2 7–23 7.12.15 8PSK / 8QAM BER Performance (LDPC) Figure 7-15.

Página 110 - Port labeled ASYNC (J17)

DMD2050E Universal Satellite Modem Technical Specifications MN-DMD2050E Revision 2 7–24 7.12.16 16QAM BER Performance (LDPC) Figure 7-16. DMD205

Página 111

DMD2050E Universal Satellite Modem Technical Specifications MN-DMD2050E Revision 2 7–25 7.12.17 BER Performance B/O/QPSK (MILSTD 188-165B or STAN

Página 113 - Chapter 4. User Interfaces

DMD-2050E Universal Satellite Modem Revision 2 Table of Contents MN-DMD2050E xii E.4.3.3 PCM-31 ...

Página 114 - 4.2.3 Numeric Keys

DMD2050E Universal Satellite Modem Technical Specifications MN-DMD2050E Revision 2 7–26 7.12.18 BER Performance 8-PSK (MILSTD 188-165B or STANAG)

Página 115 - 4.2.4 LED Lights

DMD2050E Universal Satellite Modem Technical Specifications MN-DMD2050E Revision 2 7–27 7.12.19 BER Performance 16APSK (MILSTD 188-165B or STANAG

Página 116 - 4.4 Front Panel Main Menus

DMD2050E Universal Satellite Modem Technical Specifications MN-DMD2050E Revision 2 7–28 1/2 Rate 3/4 Rate 7/8 Rate 1/2 Rate 3/4 Rate 7/8 Ra

Página 117 - 4.4.1.1 NETWORK SPEC (menu)

DMD2050E Universal Satellite Modem Technical Specifications MN-DMD2050E Revision 2 7–29 Turbo 0.495 Turbo 0.793 Turbo 0.495 Turbo 0.7931E-3

Página 118 - 4.4.1.4 DATA (menu)

DMD2050E Universal Satellite Modem Technical Specifications MN-DMD2050E Revision 2 7–30 3/4 Rate 7/8 Rate 3/4 Rate 7/8 Rate1E-3 8.9 dB 10.3

Página 119

DMD2050E Universal Satellite Modem Technical Specifications MN-DMD2050E Revision 2 7–31 1/2 Rate 3/4 Rate 7/8 Rate 1/2 Rate 3/4 Rate 7/8

Página 120

DMD2050E Universal Satellite Modem Technical Specifications MN-DMD2050E Revision 2 7–32 1/2 Rate 2/3 Rate 3/4 Rate 1/2 Rate 2/3 Rate 3/4 R

Página 121 - 4.4.1.6 AUPC (menu)

DMD2050E Universal Satellite Modem Technical Specifications MN-DMD2050E Revision 2 7–33 1/2 Rate 2/3 Rate 3/4 Rate 7/8 Rate19/20 Rate1/2 Rate

Página 122 - 4.4.1.7 LOCAL AUPC (menu)

DMD2050E Universal Satellite Modem Technical Specifications MN-DMD2050E Revision 2 7–34 7.13 AGC Output Voltage The AGC Output Voltage is a funct

Página 123

MN-DMD2050E Revision 2 A–1 Appendix A. Product Options A.1 Hardware Options These enhanced interface cards are available: DC Input Prime Power

Página 124

DMD-2050E Universal Satellite Modem Revision 2 Table of Contents MN-DMD2050E xiii APPENDIX H. ETHERNET DATA INTERFACE SETUP...

Página 125 - 4.4.1.9 ITA (menu)

DMD2050E Universal Satellite Modem Product Options MN-DMD2050E Revision 2 A–2 BLANK PAGE

Página 126 - 4.4.2.1 NETWORK SPEC (menu)

MN-DMD2050E Revision 2 B–1 Appendix B. Front Panel Upgrades and Demonstration Mode B.1 Introduction The DMD2050E Universal Satellite Modem allow

Página 127 - 4.4.2.3 IF (menu)

DMD2050E Universal Satellite Modem Front Panel Upgrade Procedure MN-DMD2050E Revision 2 B–2 B.3.1 Record the Features and Options Find and record

Página 128 - 4.4.2.4 DATA (menu)

DMD2050E Universal Satellite Modem Front Panel Upgrade Procedure MN-DMD2050E Revision 2 B–3 B.3.2 Record the Unit ID Comtech requests the Unit ID

Página 129 - 4.4.2.5 REED-SOLOMON (menu)

DMD2050E Universal Satellite Modem Front Panel Upgrade Procedure MN-DMD2050E Revision 2 B–4 B.3.4 Install the Code Use the front panel to enter t

Página 130 - Hz) between the

DMD2050E Universal Satellite Modem Front Panel Upgrade Procedure MN-DMD2050E Revision 2 B–5 B.3.5 Demonstration Mode Considerations The unit uses

Página 131 - 4.4.3.1 TX SETUP (menu)

DMD2050E Universal Satellite Modem Front Panel Upgrade Procedure MN-DMD2050E Revision 2 B–6 B.3.6 Cancel the Demonstration Mode IMPORTANT If you

Página 132

MN-DMD2050E Revision 2 C–1 Appendix C. Carrier Control C.1 Carrier Control and Alarms If a TX major alarm occurs, modulator output is muted auto

Página 133

DMD2050E Universal Satellite Modem Carrier Control MN-DMD2050E Revision 2 C–2 C.3 Carrier States These are the carrier states: • Carrier OFF •

Página 134 - 4.4.3.2 RX SETUP (menu)

DMD2050E Universal Satellite Modem Carrier Control MN-DMD2050E Revision 2 C–3 2. The output starts again automatically. C.3.4 Carrier VSAT The ca

Página 135

DMD-2050E Universal Satellite Modem Revision 2 Table of Contents MN-DMD2050E xiv Tables Table 3-1. Spectral Efficiency using DoubleTalk Carrier-

Página 136 - 4.4.3.3 GENERAL (menu)

DMD2050E Universal Satellite Modem Carrier Control MN-DMD2050E Revision 2 C–4 BLANK PAGE

Página 137 - 4.4.4.1 LINK STATUS (menu)

MN-DMD2050E Revision 2 D–1 Appendix D. Web Interface Setup Guide D.1 Introduction The web interface lets Radyne products connect and communicate

Página 138

DMD2050E Universal Satellite Modem Web Browser Setup Guide MN-DMD2050E Revision 2 D–2 D.2.2 IP Address IMPORTANT Before you set an IP address, c

Página 139 - 4.4.4.4 ITA (menu)

DMD2050E Universal Satellite Modem Web Browser Setup Guide MN-DMD2050E Revision 2 D–3 D.3.2 User Account Data IMPORTANT All entries are case-sen

Página 140 - 4.4.6.2 REMOTE CONTROL

DMD2050E Universal Satellite Modem Web Browser Setup Guide MN-DMD2050E Revision 2 D–4 IMPORTANT All entries are case-sensitive. To set up a Use

Página 141 - 4.4.6.5 TCP/IP (menu)

DMD2050E Universal Satellite Modem Web Browser Setup Guide MN-DMD2050E Revision 2 D–5 D.2 Reset a User Account Sometimes, it is necessary to rese

Página 142

DMD2050E Universal Satellite Modem Web Browser Setup Guide MN-DMD2050E Revision 2 D–6 D.4 Equipment Website Once you know that the modem is acces

Página 143 - 4.4.6.6 SNMP (menu)

DMD2050E Universal Satellite Modem Web Browser Setup Guide MN-DMD2050E Revision 2 D–7 The Introduction page shows general information, such as: •

Página 144 - 4.4.6.8 WEB (menu)

DMD2050E Universal Satellite Modem Web Browser Setup Guide MN-DMD2050E Revision 2 D–8 D.5 Web Page Appearance This page displays the Monitor and

Página 145 - 4.4.6.9 TRANSEC (menu)

DMD2050E Universal Satellite Modem Web Browser Setup Guide MN-DMD2050E Revision 2 D–9 D.6 Configure Web Browsers for the Radyne WEB Interface D

Página 146

DMD-2050E Universal Satellite Modem Revision 2 Table of Contents MN-DMD2050E xv Figures Figure 1-1. DMD2050E Universal Satellite Modem Front Pa

Página 147 - 4.4.6.10.2 FEATURES (menu)

DMD2050E Universal Satellite Modem Web Browser Setup Guide MN-DMD2050E Revision 2 D–10 D.6.2.1 Change the encoding: Click View on the Firefox men

Página 148

DMD2050E Universal Satellite Modem Web Browser Setup Guide MN-DMD2050E Revision 2 D–11 D.6.2.2 Install the Internet Explorer Tab V2 add-on The In

Página 149

DMD2050E Universal Satellite Modem Web Browser Setup Guide MN-DMD2050E Revision 2 D–12 D.6.3 Configure Chrome for the Radyne WEB Browser When you

Página 150 - 4.5.1 Terminal Mode Screens

DMD2050E Universal Satellite Modem Web Browser Setup Guide MN-DMD2050E Revision 2 D–13 D.6.3.1 Change the encoding On the Chrome address bar, cli

Página 151

DMD2050E Universal Satellite Modem Web Browser Setup Guide MN-DMD2050E Revision 2 D–14 D.6.3.2 Install the Internet Explorer Tab for Chrome The I

Página 152

DMD2050E Universal Satellite Modem Web Browser Setup Guide MN-DMD2050E Revision 2 D–15 D.6.4 Configure Safari for the Radyne WEB Browser IMPORTA

Página 153

DMD2050E Universal Satellite Modem Web Browser Setup Guide MN-DMD2050E Revision 2 D–16 D.6.4.2 Reset the Ethernet M&C port To reset the Ether

Página 154 - 5.1.2 Power Switch

DMD2050E Universal Satellite Modem Web Browser Setup Guide MN-DMD2050E Revision 2 D–17 On the Monitor & Control, Password Setup or IP Administ

Página 155 - 5.2.1 Key Loader Interface

DMD2050E Universal Satellite Modem Web Browser Setup Guide MN-DMD2050E Revision 2 D–18 D.6.4.4 Change the encoding Click View on the Safari menu

Página 156 - 5.3 Rear Panel Connectors

DMD2050E Universal Satellite Modem Web Browser Setup Guide MN-DMD2050E Revision 2 D–19 D.6.5 Configure Maxthon for the Radyne WEB Browser On the

Página 157 - 5.3.2 EXT REF (J10)

DMD-2050E Universal Satellite Modem Revision 2 Table of Contents MN-DMD2050E xvi Figure D-3. Monitor and Control Web Page ...

Página 158 - 5.3.4 ALARM (J15)

DMD2050E Universal Satellite Modem Web Browser Setup Guide MN-DMD2050E Revision 2 D–20 D.6.5.1 Change the browser mode Two browser modes are poss

Página 159 - 5.3.5 EXT CLK (J16)

DMD2050E Universal Satellite Modem Web Browser Setup Guide MN-DMD2050E Revision 2 D–21 D.6.5.2 Change the encoding On the Monitor & Control p

Página 160 - 5.3.6 ASYNC (J17)

DMD2050E Universal Satellite Modem Web Browser Setup Guide MN-DMD2050E Revision 2 D–22 BLANK PAGE

Página 161 - 5.3.8 MIL-188-114A (J19)

MN-DMD2050E Revision 2 E–1 Appendix E. Drop and Insert (Standard and Efficient Options) E.1 Introduction Drop and Insert (D&I) functions

Página 162

DMD2050E Universal Satellite Modem Efficient Drop and Insert MN-DMD2050E Revision 2 E–2 Objective Menu Path Requirement Find the G.703 interface c

Página 163 - Troubleshooting

DMD2050E Universal Satellite Modem Efficient Drop and Insert MN-DMD2050E Revision 2 E–3 Figure E-1. Looped Modems Figure E-2 Looped Modems wi

Página 164 - 6.2 Troubleshooting

DMD2050E Universal Satellite Modem Efficient Drop and Insert MN-DMD2050E Revision 2 E–4 E.4 Functional Descriptions E.4.1 Drop Only When Drop is

Página 165 - 6.3.2 Major Rx Alarms

DMD2050E Universal Satellite Modem Efficient Drop and Insert MN-DMD2050E Revision 2 E–5 Figure E-4 Insert Only with Eternal Frame Source Figure

Página 166 - 6.3.3 Minor Tx Alarms

DMD2050E Universal Satellite Modem Efficient Drop and Insert MN-DMD2050E Revision 2 E–6 E.4.3 Data Formats The terrestrial data formats compatibl

Página 167 - 6.3.3.1 Minor Rx Alarms

DMD2050E Universal Satellite Modem Efficient Drop and Insert MN-DMD2050E Revision 2 E–7 drop and n timeslots to insert where n = 1, 2, 3, 4, 5, 6,

Página 168

xix PREFACE About this Manual This manual gives installation and operation information for the Comtech EF Data DMD2050E Universal Product Modem.

Página 169

DMD2050E Universal Satellite Modem Efficient Drop and Insert MN-DMD2050E Revision 2 E–8 SATCh TS Enter to Edit Any changes made in these displa

Página 170 - 6.4.1.2 Minor Alarms

DMD2050E Universal Satellite Modem Efficient Drop and Insert MN-DMD2050E Revision 2 E–9 Example : For a modem w/ Drop and Insert enabled at a data

Página 171 - 6.4.3 Latched Alarms

DMD2050E Universal Satellite Modem Efficient Drop and Insert MN-DMD2050E Revision 2 E–10 Map Copy RX EDIT > RX ACTIVE 4. Press &l

Página 172

DMD2050E Universal Satellite Modem Efficient Drop and Insert MN-DMD2050E Revision 2 E–11 E.5.1 Data Rate Data Rate affects the Drop and Insert fu

Página 173 - 6.4.4 Backward Alarms

DMD2050E Universal Satellite Modem Efficient Drop and Insert MN-DMD2050E Revision 2 E–12 n = 12, data rate = 768000 n = 15, data rate = 960000 n =

Página 174 - 6.5 IBS Alarms and Actions

DMD2050E Universal Satellite Modem Efficient Drop and Insert MN-DMD2050E Revision 2 E–13 E.5.3.1 Insert Terrestrial Frame Source The Insert Terre

Página 175 - 7.1 Modulator

DMD2050E Universal Satellite Modem Efficient Drop and Insert MN-DMD2050E Revision 2 E–14 Under Tx D&I: Set Drop Mode = T1-D4

Página 176 - 7.2 Demodulator

DMD2050E Universal Satellite Modem Efficient Drop and Insert MN-DMD2050E Revision 2 E–15 Set Conv Enc = 3/4 Rate VIT Under Interface: Unde

Página 177 - 7.4 Monitor and Control

DMD2050E Universal Satellite Modem Efficient Drop and Insert MN-DMD2050E Revision 2 E–16 Set Rx Type according to your hardware configuration

Página 178

DMD2050E Universal Satellite Modem Efficient Drop and Insert MN-DMD2050E Revision 2 E–17 E.5.4.1 D&I Clock Setup Examples Figure E-7 Trans

Página 179 - 7.11.1 Non-DVB

DMD2050E Universal Product Modem Revision 2 Preface MN-DMD2050E xx Electrical Safety The DMD2050E has been shown to comply with the EN 60950 Safety

Página 180

DMD2050E Universal Satellite Modem Efficient Drop and Insert MN-DMD2050E Revision 2 E–18 Figure E-9 Rx Only With Trunk Figure E-10 Rx Only No

Página 181 - 7.11.2 DVB

DMD2050E Universal Satellite Modem Efficient Drop and Insert MN-DMD2050E Revision 2 E–19 E.6 D&I Maps and Map Editing The Drop and Insert mul

Página 182

DMD2050E Universal Satellite Modem Efficient Drop and Insert MN-DMD2050E Revision 2 E–20 Therefore, in this case only the first six entries of the

Página 183 - 7.12 BER Specifications

DMD2050E Universal Satellite Modem Efficient Drop and Insert MN-DMD2050E Revision 2 E–21 map through the modem’s LCD; when editing is complete, th

Página 184 -

DMD2050E Universal Satellite Modem Efficient Drop and Insert MN-DMD2050E Revision 2 E–22 time slots of the T1 or E1 frame. The Multiplexer would

Página 185 - Viterbi Decoder Reed

DMD2050E Universal Satellite Modem Efficient Drop and Insert MN-DMD2050E Revision 2 E–23 This would be used with T1 frames where channels 1 throug

Página 186 - Turbo Decoder

DMD2050E Universal Satellite Modem Efficient Drop and Insert MN-DMD2050E Revision 2 E–24 E.8 Prerequisite In order for a modem to be configured f

Página 187 - Trellis

DMD2050E Universal Satellite Modem Efficient Drop and Insert MN-DMD2050E Revision 2 E–25 E.9 Efficient Drop and Insert Mode With Efficient Drop a

Página 188

DMD2050E Universal Satellite Modem Efficient Drop and Insert MN-DMD2050E Revision 2 E–26 600 station in-band rate. In most cases, this

Página 189 - Viterbi

DMD2050E Universal Satellite Modem Efficient Drop and Insert MN-DMD2050E Revision 2 E–27 E.9.4 Calculating the Efficient D&I Rate with Enhanc

Página 190 - Reed Solomon

DMD2050E Universal Product Modem Revision 2 Preface MN-DMD2050E xxi Environmental Do not operate the DMD2050E in an environment where the unit is ex

Página 191

DMD2050E Universal Satellite Modem Efficient Drop and Insert MN-DMD2050E Revision 2 E–28 X = Truncation of (1.92) X = 1 Add 1 * 5 * 125 bps to

Página 192

MN-DMD2050E Revision 2 F–1 Appendix F. TCP/IP Ethernet Setup F.1 Introduction The modem supports SNMP, FTP protocols and the Web Browser. Utili

Página 193

DMD2050E Universal Satellite Modem TCP/IP Ethernet Setup MN-DMD2050E Revision 2 F–2 • MODEM IP ADDR 010.000.000.001 • SERVER IP ADDR 010.0

Página 194

DMD2050E Universal Satellite Modem TCP/IP Ethernet Setup MN-DMD2050E Revision 2 F–3 and loop back addresses will not be allowed. Example Server I

Página 195

DMD2050E Universal Satellite Modem TCP/IP Ethernet Setup MN-DMD2050E Revision 2 F–4 F.4 Ethernet Test F.4.1 Connecting the Modem Ethernet Cable

Página 196 - LDPC Decoder

DMD2050E Universal Satellite Modem TCP/IP Ethernet Setup MN-DMD2050E Revision 2 F–5 1. Click the Start button. 2. Select Settings and click Co

Página 197

DMD2050E Universal Satellite Modem TCP/IP Ethernet Setup MN-DMD2050E Revision 2 F–6 Internet Protocol (TCP/IP) Properties 9. Select “Use the fo

Página 198

DMD2050E Universal Satellite Modem TCP/IP Ethernet Setup MN-DMD2050E Revision 2 F–7 F.5 Testing the Ethernet Connection using the Ping Program (O

Página 199

DMD2050E Universal Satellite Modem TCP/IP Ethernet Setup MN-DMD2050E Revision 2 F–8 4. If the ping is unsuccessful the screen will display: C:\>

Página 200 - MILSTD 188-165B

MN-DMD2050E Revision 2 G–1 Appendix G. AUPC Operation G.1 Automatic Uplink Power Control (AUPC Operation) The modem has an optional built-in pro

Página 201 - MILSTD 188

DMD2050E Universal Product Modem Revision 2 Preface MN-DMD2050E xxii CE Mark Comtech EF Data declares that the DMD2050E meets the necessary requirem

Página 202

DMD2050E Universal Satellite Modem AUPC Operation MN-DMD2050E Revision 2 G–2 drop in the remote Eb/No, it slowly begins to raise the output power,

Página 203

DMD2050E Universal Satellite Modem AUPC Operation MN-DMD2050E Revision 2 G–3 The local receiver must be tuned and locked to the transmitter and th

Página 204

DMD2050E Universal Satellite Modem AUPC Operation MN-DMD2050E Revision 2 G–4 When the rain diminishes, Local modem will see the remote Es/No begin

Página 205

MN-DMD2050E Revision 2 H–1 Appendix H. Ethernet Data Interface Setup H.1 Configuring the modem to use the Ethernet Data Interface (Optional) Whe

Página 206

DMD2050E Universal Satellite Modem Ethernet Data Interface Setup MN-DMD2050E Revision 2 H–2 When Ethernet Data Interface is selected, the Tx Clock

Página 207

DMD2050E Universal Satellite Modem Ethernet Data Interface Setup MN-DMD2050E Revision 2 H–3 When Port 4 is selected for Daisy Chain, any data rece

Página 208 - 7.13 AGC Output Voltage

DMD2050E Universal Satellite Modem Ethernet Data Interface Setup MN-DMD2050E Revision 2 H–4 H.1.5 Setting Up The DMD2050E Ethernet Bridge To Opera

Página 209 - Appendix A. Product Options

DMD2050E Universal Satellite Modem Ethernet Data Interface Setup MN-DMD2050E Revision 2 H–5 H.1.6 Packet Statistics The following statistics are a

Página 210

DMD2050E Universal Satellite Modem Ethernet Data Interface Setup MN-DMD2050E Revision 2 H–6 BLANK PAGE

Página 211 - B.3 Procedures

MN-DMD2050E Revision 2 I–1 Appendix I. Strap Codes I.1 Strap Codes The Strap Code is a quick set key that sets many of the modem parameters. For

Página 212

DMD2050E Universal Product Modem Revision 2 Preface MN-DMD2050E xxiii Product support On the web http://www.comtechefdata.com/support.asp Return mat

Página 213 - B.3.2 Record the Unit ID

DMD2050E Universal Satellite Modem Strap Codes MN-DMD2050E Revision 2 I–2 NOTE Dis = Disable in Table I-1. Table I-1. Strap Codes Strap Code (D

Página 214 - B.3.4 Install the Code

DMD2050E Universal Satellite Modem Strap Codes MN-DMD2050E Revision 2 I–3 Strap Code (Decimal) Data Rate (Kbps) Overhead Code Rate Type Framing Ty

Página 215

DMD2050E Universal Satellite Modem Strap Codes MN-DMD2050E Revision 2 I–4 Strap Code (Decimal) Data Rate (Kbps) Overhead Code Rate Type Framing Ty

Página 216

DMD2050E Universal Satellite Modem Strap Codes MN-DMD2050E Revision 2 I–5 Strap Code (Decimal) Data Rate (Kbps) Overhead Code Rate Type Framing Ty

Página 217 - Appendix C. Carrier Control

DMD2050E Universal Satellite Modem Strap Codes MN-DMD2050E Revision 2 I–6 I.2 Sample Applications The following section provides brief applicatio

Página 218 - C.3.3 Carrier AUTO

DMD2050E Universal Satellite Modem Strap Codes MN-DMD2050E Revision 2 I–7 I.2.1 Operational Case Examples IMPORTANT Make sure to set the data r

Página 219 - C.3.5 CARRIER RTS

DMD2050E Universal Satellite Modem Strap Codes MN-DMD2050E Revision 2 I–8 Set desired Tx frequency and power level Turn IF on Demodulator

Página 220

DMD2050E Universal Satellite Modem Strap Codes MN-DMD2050E Revision 2 I–9 I.2.1.2 Case 2: IBS 1.544 Mbps, 3/4 Rate Viterbi Start with the Data R

Página 221 - Setup Guide

DMD2050E Universal Satellite Modem Strap Codes MN-DMD2050E Revision 2 I–10 Demodulator: Method 1 - Under Interface Menu: Set Interface type Se

Página 222 - D.3.1 Default User Accounts

DMD2050E Universal Satellite Modem Strap Codes MN-DMD2050E Revision 2 I–11 I.2.1.3 Case 3: Closed Network, 3/4 Rate Viterbi, IBS Overhead Start

Página 223 - D.1 User Account Setup

ER-DMD2050E-EA2 Rev - PLM C-0028800 Errata A for MN-DMD2050E Rev 2 Comtech EF Data Documentation Update Subject: Chapter 3, Theory of Operati

Página 224 - D.1.2 Edit the Access Group

DMD2050E Universal Product Modem Revision 2 Preface MN-DMD2050E xxiv Warranty Policy Comtech EF Data products are warranted against defects in mater

Página 225 - D.3 Confirmation

DMD2050E Universal Satellite Modem Strap Codes MN-DMD2050E Revision 2 I–12 Demodulator: Method 1 - Under Interface Menu: Set Interface type Se

Página 226 - D.4 Equipment Website

DMD2050E Universal Satellite Modem Strap Codes MN-DMD2050E Revision 2 I–13 I.2.1.4 Case 4: Loop Timing Example Method 1 - Under Interface Menu:

Página 227

DMD2050E Universal Satellite Modem Strap Codes MN-DMD2050E Revision 2 I–14 BLANK PAGE

Página 228 - D.5 Web Page Appearance

MN-DMD2050E Revision 2 J–1 Appendix J. ITA Operation J.1 Information Throughput Adaptation (ITA Operation) Information Throughput Adaptation (IT

Página 229

DMD2050E Universal Satellite Modem ITA Operation MN-DMD2050E Revision 2 J–2 J.1.1 Properties of ITA on the DMD2050E: • The DMD2050E output power

Página 230

DMD2050E Universal Satellite Modem ITA Operation MN-DMD2050E Revision 2 J–3 J.1.2 Basic Setup (Example) The modems will be initially configured i

Página 231

DMD2050E Universal Satellite Modem ITA Operation MN-DMD2050E Revision 2 J–4 J.1.2.1 Initial DMD2050E Modem Setup Table J-2 - Initial Modem Setup

Página 232

DMD2050E Universal Satellite Modem ITA Operation MN-DMD2050E Revision 2 J–5 Figure J-1 - Initial Setup DMD2050E, Modulator IF

Página 233 - D.6.3.1 Change the encoding

DMD2050E Universal Satellite Modem ITA Operation MN-DMD2050E Revision 2 J–6 Figure J-2 - Initial Setup DMD2050E, Modulator Data

Página 234

DMD2050E Universal Satellite Modem ITA Operation MN-DMD2050E Revision 2 J–7 Figure J-3 - Initial Setup DMD2050E, Modulator ITA

Página 235

MN-DMD2050E Revision 2 1– 1 Chapter 1. Introduction 1.1 Overview The new DMD2050E Satellite Modem (Figure 1-1) breaks new ground in flexibility a

Página 236

DMD2050E Universal Satellite Modem ITA Operation MN-DMD2050E Revision 2 J–8 Figure J-4 - Initial Setup DMD2050E, Demodulator IF

Página 237

DMD2050E Universal Satellite Modem ITA Operation MN-DMD2050E Revision 2 J–9 Figure J-5 - Initial Setup DMD2050E, Demodulator Data

Página 238 - D.6.4.4 Change the encoding

DMD2050E Universal Satellite Modem ITA Operation MN-DMD2050E Revision 2 J–10 Figure J-6 - Initial Setup DMD2050E, Demodulator ITA At this point

Página 239

DMD2050E Universal Satellite Modem ITA Operation MN-DMD2050E Revision 2 J–11 Table J-3 - ITA Setup FW: F05280-AH28 REV 4.4.28 (7/06 9:47)MAIN

Página 240

DMD2050E Universal Satellite Modem ITA Operation MN-DMD2050E Revision 2 J–12 The ITA Menu Functions and their descriptions are shown in Table J-4

Página 241 - D.6.5.2 Change the encoding

DMD2050E Universal Satellite Modem ITA Operation MN-DMD2050E Revision 2 J–13 Table J-5. Receive ITA Functions Function AUPC Available Options Desc

Página 242

DMD2050E Universal Satellite Modem ITA Operation MN-DMD2050E Revision 2 J–14 Table J-6 – ITA Waveform Masks (Modulator UUT) DMD2050E MENU SETTINGS

Página 243 - E.2 System Requirements

DMD2050E Universal Satellite Modem ITA Operation MN-DMD2050E Revision 2 J–15 Table J-7 – ITA Waveform Masks (Demodulator UUT) DMD2050E MENU SETTIN

Página 244 - E.3 Configuration Examples

DMD2050E Universal Satellite Modem ITA Operation MN-DMD2050E Revision 2 J–16 Table J-8 – ITA Waveform Masks (Reference Modulator) DMD2050E MENU SE

Página 245 - Figure E-1. Looped Modems

DMD2050E Universal Satellite Modem ITA Operation MN-DMD2050E Revision 2 J–17 Table J-9 – ITA Waveform Masks (Reference Demodulator) DMD2050E MENU

Página 246 - E.4.2 Insert Only

DMD2050E Universal Product Modem Introduction MN-DMD2050E Revision 2 1– 2 The DMD2050E supports a full range of Industry Standard Interfaces that i

Página 247

DMD2050E Universal Satellite Modem ITA Operation MN-DMD2050E Revision 2 J–18 Figure J-7 - Initial Setup DMD2050E, Modulator ITA

Página 248 - E.4.3.3 PCM-31

DMD2050E Universal Satellite Modem ITA Operation MN-DMD2050E Revision 2 J–19 Figure J-8 - Initial Setup DMD2050E, Demodulator ITA To setup ITA Mo

Página 249 - E.4.3.6 T1-ESF/T1-ESF-S

DMD2050E Universal Satellite Modem ITA Operation MN-DMD2050E Revision 2 J–20 Figure J-9- Initial Setup DMD2050E, Modulator ITA (Enabled)

Página 250

DMD2050E Universal Satellite Modem ITA Operation MN-DMD2050E Revision 2 J–21 Figure J-10 - Initial Setup DMD2050E, Demodulator ITA (Enabled)

Página 251

DMD2050E Universal Satellite Modem ITA Operation MN-DMD2050E Revision 2 J–22 Figure J-11 –DMD2050E I/Q for BPSK 2/3

Página 252

DMD2050E Universal Satellite Modem ITA Operation MN-DMD2050E Revision 2 J–23 Figure J-12 –DMD2050E ITA Status for QPSK 2/3

Página 253 - E.5.1 Data Rate

DMD2050E Universal Satellite Modem ITA Operation MN-DMD2050E Revision 2 J–24 Figure J-13 –DMD2050E I/Q for QPSK 2/3

Página 254

DMD2050E Universal Satellite Modem ITA Operation MN-DMD2050E Revision 2 J–25 Figure J-14 –DMD2050E ITA Status for 16APSK 1/2

Página 255 - Example 1:

DMD2050E Universal Satellite Modem ITA Operation MN-DMD2050E Revision 2 J–26 Figure J-15 –DMD2050E I/Q for 16APSK 1/2

Página 256

DMD2050E Universal Satellite Modem ITA Operation MN-DMD2050E Revision 2 J–27 Figure J-16 –DMD2050E ITA Status for 8PSK 3/4

Página 257 - Example 2:

DMD2050E Universal Product Modem Introduction MN-DMD2050E Revision 2 1– 3 • Switchable between spur-free 70/140 MHz and L-Band operations • AC or

Página 258

DMD2050E Universal Satellite Modem ITA Operation MN-DMD2050E Revision 2 J–28 Figure J-17 –DMD2050E I/Q for 8PSK 3/4

Página 259

DMD2050E Universal Satellite Modem ITA Operation MN-DMD2050E Revision 2 J–29 Figure J-18 –DMD2050E ITA Status for 16APSK 7/8

Página 260

DMD2050E Universal Satellite Modem ITA Operation MN-DMD2050E Revision 2 J–30 Figure J-19 –DMD2050E I/Q for 16APSK 7/8 At this point changing the

Página 261

Copyright © Comtech EF Data, 2011. All rights reserved. Printed in the USA. Comtech EF Data, 2114 West 7th Street, Tempe, Arizona 85281 USA, 480.333.

Página 262

Licensed Software Revision 0 TRANSEC Module AD-TRANSEC-LICNS 2 GNU GENERAL PUBLIC LICENSE Version 2, June 1991 Copyright (C) 1989, 1991

Página 263

Licensed Software Revision 0 TRANSEC Module AD-TRANSEC-LICNS 3 either of that version or of any later version published by the Free Software Founda

Página 264

Licensed Software Revision 0 TRANSEC Module AD-TRANSEC-LICNS 4 writing it). Whether that is true depends on what the Library does and what the pro

Página 265

Licensed Software Revision 0 TRANSEC Module AD-TRANSEC-LICNS 5 It is not the purpose of this section to induce you to infringe any patents or other

Página 266 - E.8 Prerequisite

Licensed Software Revision 0 TRANSEC Module AD-TRANSEC-LICNS 6 * This can be in the form of a textual message at program startup or * in document

Página 267

Licensed Software Revision 0 TRANSEC Module AD-TRANSEC-LICNS 7 Darren Tucker Sun Microsystems The SCO Group * Redistribution and use in sou

Página 268

DMD2050E Universal Product Modem Introduction MN-DMD2050E Revision 2 1– 4 1.2.4 Interfaces Industry-standard interfaces include: • MIL-188-114 (

Página 269

Licensed Software Revision 0 TRANSEC Module AD-TRANSEC-LICNS 8 This page is intentionally blank.

Página 271 - F.1 Introduction

2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 • 333 • 2200 PHONE 480 • 333 • 2161 FAX

Página 272

DMD2050E Universal Product Modem Introduction MN-DMD2050E Revision 2 1– 5 1.2.7.1 Dimensional Envelope

Página 273

DMD2050E Universal Product Modem Introduction MN-DMD2050E Revision 2 1– 6 1.3 Configurations and Options The DMD2050E has several configuration p

Página 274 - Network)

MN-DMD2050E Revision 2 2–1 Chapter 2. Installation 2.1 Unpacking and Inspection CAUTION Do not damage the carton contents with a cutting tool.

Página 275

DMD2050E Universal Satellite Modem Installation MN-DMD2050E Revision 2 2–2 2.2 Installation Safety The unit is shipped fully assembled. Do not r

Página 276

DMD2050E Universal Satellite Modem Installation MN-DMD2050E Revision 2 2–3 2.3.1 Location The unit is intended for indoor use only. Do not instal

Página 277

ER-DMD2050E-EA2 Rev - PLM C-0028800 Blank Page

Página 278

DMD2050E Universal Satellite Modem Installation MN-DMD2050E Revision 2 2–4 2.3.5 Cables To meet EMC directives, make sure to use shielded cables

Página 279 - Appendix G. AUPC Operation

DMD2050E Universal Satellite Modem Installation MN-DMD2050E Revision 2 2–5 IMPORTANT Strap Code 26 can set the following modem configuration. T

Página 280 - G.1.3 Near Side AUPC

DMD2050E Universal Satellite Modem Installation MN-DMD2050E Revision 2 2–6 BLANK PAGE

Página 281 - G.1.4 EBEM AUPC

MN-DMD2050E Revision 2 3–1 Chapter 3. Theory of Operation 3.1 DMD2050E Hardware The DMD2050E is based on a two printed circuit card (minimum con

Página 282

DMD2050E Universal Satellite Modem Theory of Operation MN-DMD2050E Revision 2 3–2 3.1.1 DMD2050E L-Band/IF Printed Circuit Card The L-Band/IF Pri

Página 283 - Interface Setup

DMD2050E Universal Satellite Modem Theory of Operation MN-DMD2050E Revision 2 3–3 3.1.2 DMD2050E Baseband Processing Printed Circuit Card The adv

Página 284 - H.1.2 Ethernet Daisy Chain

DMD2050E Universal Satellite Modem Theory of Operation MN-DMD2050E Revision 2 3–4 Figure 3-3. DMD2050E Baseband Processing Card Block Diagram The

Página 285 - H.1.4 Ethernet QOS Queue

DMD2050E Universal Satellite Modem Theory of Operation MN-DMD2050E Revision 2 3–5 The M&C System is based on a powerful microprocessor with a

Página 286

DMD2050E Universal Satellite Modem Theory of Operation MN-DMD2050E Revision 2 3–6 Figure 3-4. DMD2050E Universal Satellite Modem Functional Block

Página 287 - H.1.6 Packet Statistics

DMD2050E Universal Satellite Modem Theory of Operation MN-DMD2050E Revision 2 3–7 The Reed-Solomon Encoder, encodes the data into Reed-Solomon Blo

Página 288

ER-DMD2050E-EB2 Rev - PLM C-0028804 Errata B for MN-DMD2050E Rev 2 Comtech EF Data Documentation Update Subject: Chapter 3 and Chapter 4 refe

Página 289 - Appendix I. Strap Codes

DMD2050E Universal Satellite Modem Theory of Operation MN-DMD2050E Revision 2 3–8 • Modem Status, Alarms & Contact Closures (Section 3.2.9) 3

Página 290

DMD2050E Universal Satellite Modem Theory of Operation MN-DMD2050E Revision 2 3–9 3.2.8 Ethernet M&C Port This port is dedicated for Ethernet

Página 291

DMD2050E Universal Satellite Modem Theory of Operation MN-DMD2050E Revision 2 3–10 3.3 Internal Clock The time and date is kept in order to ‘tim

Página 292

DMD2050E Universal Satellite Modem Theory of Operation MN-DMD2050E Revision 2 3–11 Figure 3-5. Loopback Functional Block Diagram

Página 293

DMD2050E Universal Satellite Modem Theory of Operation MN-DMD2050E Revision 2 3–12 Figure 3-6. Loopback Functional Block Diagram

Página 294 - I.2 Sample Applications

DMD2050E Universal Satellite Modem Theory of Operation MN-DMD2050E Revision 2 3–13 Figure 3-7. Loopback Functional Block Diagram 3.5 DMD2050E Cl

Página 295

DMD2050E Universal Satellite Modem Theory of Operation MN-DMD2050E Revision 2 3–14 SDTTTx CLKSRCHigh Stability OscillatorSTCLOCK & DATAEXT REF

Página 296

DMD2050E Universal Satellite Modem Theory of Operation MN-DMD2050E Revision 2 3–15 3.5.2.1 SCTE: Serial Clock Transmit External The SCTE clock is

Página 297

DMD2050E Universal Satellite Modem Theory of Operation MN-DMD2050E Revision 2 3–16 3.5.3 RX Buffer Clock Options The modem supports a number of

Página 298

DMD2050E Universal Satellite Modem Theory of Operation MN-DMD2050E Revision 2 3–17 3.5.3.3 SCT: Serial Clock Transmit If SCT clock is selected

Página 299

DMD2050E Universal Satellite Modem User Interfaces MN-DMD2050E Revision 2 4–31 4.4.6.6 SNMP (menu) A description of OID organization is provided

Página 300

DMD2050E Universal Satellite Modem Theory of Operation MN-DMD2050E Revision 2 3–18 3.6 Transmit Timing Options As shown in Figure 3-7, Transmit T

Página 301

DMD2050E Universal Satellite Modem Theory of Operation MN-DMD2050E Revision 2 3–19 3.6.4 Ethernet Data Interface (Optional) The modem support a s

Página 302

DMD2050E Universal Satellite Modem Theory of Operation MN-DMD2050E Revision 2 3–20 3.8 Ebem Framing Unit The DMD2050E EBEM framing Unit provides

Página 303 - Appendix J. ITA Operation

DMD2050E Universal Satellite Modem Theory of Operation MN-DMD2050E Revision 2 3–21 3.10 FIPs TRANSEC Module The DMD2050E FIPS Security Module pro

Página 304

DMD2050E Universal Satellite Modem Theory of Operation MN-DMD2050E Revision 2 3–22 IdleWaiting for Embedded ChannelTX OFFEvent: TX ONAction: NoneW

Página 305 - J.1.2 Basic Setup (Example)

DMD2050E Universal Satellite Modem Theory of Operation MN-DMD2050E Revision 2 3–23 IdleWaiting for Key RolloverStartupEvent: Key Agreement Messag

Página 306

DMD2050E Universal Satellite Modem Theory of Operation MN-DMD2050E Revision 2 3–24 3.10.1.2 Key Agreement Algorithm The key agreement algorithm

Página 307

DMD2050E Universal Satellite Modem Theory of Operation MN-DMD2050E Revision 2 3–25 After you have enabled Encryption from the front panel, set up

Página 308

DMD2050E Universal Satellite Modem Theory of Operation MN-DMD2050E Revision 2 3–26 Figure 3-12. DMD2050E Handheld Key Loader 3.11 DoubleTalk Car

Página 309

DMD2050E Universal Satellite Modem Theory of Operation MN-DMD2050E Revision 2 3–27 3.11.1 What is DoubleTalk Carrier-in-Carrier? The DMD2050E Do

Página 310

DMD2050E Universal Satellite Modem Theory of Operation MN-DMD2050E Revision 2 3–8  Modem Status, Alarms & Contact Closures (Section 3.2.9) 3

Página 311

DMD2050E Universal Satellite Modem Theory of Operation MN-DMD2050E Revision 2 3–28 • The transponder needs to be “bent-pipe” – meaning no on-boar

Página 312

DMD2050E Universal Satellite Modem Theory of Operation MN-DMD2050E Revision 2 3–29 Figure 3-13. Conceptual Block Diagram In a number of ways, CnC

Página 313 - Table J-3 - ITA Setup

DMD2050E Universal Satellite Modem Theory of Operation MN-DMD2050E Revision 2 3–30 • The ratio of power spectral density is normally less than 11

Página 314

DMD2050E Universal Satellite Modem Theory of Operation MN-DMD2050E Revision 2 3–31 Figure 3-11 shows the same link using the DMD2050E equipped wi

Página 315

DMD2050E Universal Satellite Modem Theory of Operation MN-DMD2050E Revision 2 3–32 Traditional Full Duplex Link Duplex Link with Doub

Página 316

DMD2050E Universal Satellite Modem Theory of Operation MN-DMD2050E Revision 2 3–33 QPSK 3/4 1.50 3.00 QPSK 7/8 1.75 3.50 8-QAM 2/3 2.00 4.00

Página 317

DMD2050E Universal Satellite Modem Theory of Operation MN-DMD2050E Revision 2 3–34 Figure 3-17. DoubleTalk Carrier-in-Carrier Signals Referring t

Página 318

DMD2050E Universal Satellite Modem Theory of Operation MN-DMD2050E Revision 2 3–35 Unwanted interfering signal suppression of 30 dB or more has be

Página 319

DMD2050E Universal Satellite Modem Theory of Operation MN-DMD2050E Revision 2 3–36 involves trying different FEC and modulation combinations with

Página 320

DMD2050E Universal Satellite Modem Theory of Operation MN-DMD2050E Revision 2 3–37 Carrier-in-Carrier link design involved trying different Modul

Página 321

ER-DMD2050E-EB2 Rev - PLM C-0028804 Blank Page

Página 322

DMD2050E Universal Satellite Modem Theory of Operation MN-DMD2050E Revision 2 3–38 Link parameters and LST summary for QPSK, LDPC 2/3 with Carrier

Página 323

DMD2050E Universal Satellite Modem Theory of Operation MN-DMD2050E Revision 2 3–39 The link budget summary for the different MODCOD combinations i

Página 324

DMD2050E Universal Satellite Modem Theory of Operation MN-DMD2050E Revision 2 3–40 While the traditional link was based on QPSK, TPC 3/4 and requi

Página 325

DMD2050E Universal Satellite Modem Theory of Operation MN-DMD2050E Revision 2 3–41 3.11.9.3 Power Limited Links Carrier-in-Carrier can provide su

Página 326

DMD2050E Universal Satellite Modem Theory of Operation MN-DMD2050E Revision 2 3–42 Whereas the original link used 8-PSK TPC 3/4, the Carrier-in-Ca

Página 327

DMD2050E Universal Satellite Modem Theory of Operation MN-DMD2050E Revision 2 3–43 Step Procedure 1c Make sure CnC function is OFF at both sites.

Página 328

DMD2050E Universal Satellite Modem Theory of Operation MN-DMD2050E Revision 2 3–44 3.11.11 Validating Carrier-in-Carrier Performance Carrier-in-C

Página 329

DMD2050E Universal Satellite Modem Theory of Operation MN-DMD2050E Revision 2 3–45 3.11.12 Operational References 3.11.12.1 Carrier-in-Carrier L

Página 330

DMD2050E Universal Satellite Modem Theory of Operation MN-DMD2050E Revision 2 3–46 3.11.12.2 Estimating PSD Ratio PSD can be estimated from a lin

Página 331

DMD2050E Universal Satellite Modem Theory of Operation MN-DMD2050E Revision 2 3–47 3.11.12.4 Estimating PSD Ratio from Satmaster 3.11.12.5 Esti

Página 332

Copyright © Comtech EF Data, 2013. All rights reserved. Printed in the USA. Comtech EF Data, 2114 West 7th Street, Tempe, Arizona 85281 USA, 480.333.

Página 333 - TRANSEC Module

DMD2050E Universal Satellite Modem Theory of Operation MN-DMD2050E Revision 2 3–48 3.11.13 DoubleTalk Carrier-in-Carrier Specifications Operatin

Página 334

DMD2050E Universal Satellite Modem Theory of Operation MN-DMD2050E Revision 2 3–49 3.11.14 Carrier-in-Carrier Summary Comtech EF Data’s DoubleTal

Página 335

DMD2050E Universal Satellite Modem Theory of Operation MN-DMD2050E Revision 2 3–50 Leased bandwidth Almost all satellite operators charge for the

Página 336

DMD2050E Universal Satellite Modem Theory of Operation MN-DMD2050E Revision 2 3–51 C/N = C/No – 10 log B [where B is bandwidth in Hz] Eb/No = C/No

Página 337

DMD2050E Universal Satellite Modem Theory of Operation MN-DMD2050E Revision 2 3–52 exhibits inherently low decoding latency compared with TCC, and

Página 338

DMD2050E Universal Satellite Modem Theory of Operation MN-DMD2050E Revision 2 3–53 It can be seen from this graph that, for Code Rates above 3/4,

Página 339

DMD2050E Universal Satellite Modem Theory of Operation MN-DMD2050E Revision 2 3–54 Mode Code Rate/Modulation Lower Data Rate Limit (kbps) Upper Da

Página 340

DMD2050E Universal Satellite Modem Theory of Operation MN-DMD2050E Revision 2 3–55 Table 3-3. Comparison of all Comtech EF Data TPC and LDPC Modes

Página 341

DMD2050E Universal Satellite Modem Theory of Operation MN-DMD2050E Revision 2 3–56 3.12.2 TPC and LDPC Summary FOR AGAINST Exceptionally good BE

Página 342 - • 333 • 2161 FAX

DMD2050E Universal Satellite Modem Theory of Operation MN-DMD2050E Revision 2 3–57 When the signal is received and demodulated by the Receiving Mo

Comentários a estes Manuais