RCS20 M:N Redundancy Switch Revision 15
User Interfaces MN-RCS20 and CD-RCS20
4–46
4.3.2.20 COMBINE IFL (IFS L-Band Demodulator Only)
This screen allows the user to combine the IFS L-Band (enable 8-input mode) or return the switch to its
original 2x4 (enable 4-input mode) configuration. The 8-input mode configuration is available only in the
1:9 configuration and only for the IFS L-Band Demodulator.
Key Label Function
S1 TOG MODE Press to toggle between NO and YES.
S2 --- N/A
S3 --- N/A
S4 RETURN Press to return to the BANK CONTROL CONFIGURATION Screen.
Numeric Keypad --- Press <ENT> to accept change.
4.3.2.21 CARRIER-IN-CARRIER MODEMS
This screen allows the use of the RCS20 redundancy switch with CnC-capable Radyne/ Comtech EF
Data modems as listed:
Modem Model Number Minimum Level of M&C Firmware needed
DMD20 F05058-CF (9.4)
DMD50 F05585-AF (4.2)
DMD2050 F05280-AF (4.2)
DMD2050E F05280-AH (4.4)
COMBINE DEMOD IFL
COMBINE IFL: NO
TOG MODE RETURN
CARRIER-IN-CARRIER MODEMS
CNC SWITCHING: YES
CNC NEXT