RCS20 M:N Redundancy Switch Revision 15
User Interfaces MN-RCS20 and CD-RCS20
4–13
4.3.1.7 BACKUP MODE 1 SELECT
This screen allows the user to select the mode of backup operation for Backup Channel 1 (Channel 0).
The following backup modes are available:
•
Manual - allows the operator to force backups to occur even if prime channel modems have not
failed.
•
Non-Revertive - allows automatic backups to occur when prime channels fail, but once a channel
is backed up, it will remain backed up until manually reset by the operator.
•
Revertive - allows automatic backups to occur when prime channels fail, and after a channel is
backed up, if the prime channel clears its error, the backup can become available for another
prime channel.
4.3.1.7.1 Programming steps:
1. Press <MANUAL> to configure Backup Channel 1 for manual operation. The switch parameter
table will be updated immediately.
2. Press <NON-REV> to configure Backup Channel 1 for automatic non-revertive operation. The
switch parameter table will be updated immediately.
3. Press <REVERT> to configure Backup Channel 1 for automatic revertive operation. The switch
parameter table will be updated immediately.
4. Press <CLR> or <RETURN> to abort programming (no switch parameters changed). The display
will return to Config Switch Screen 4 (Backup Mode Configuration).
Key Label Function
S1 MANUAL
Sets the backup unit for Manual Backup Mode. The switch parameter table will be
updated immediately.
S2
NON-
REV
Sets the backup unit for Non-Revertive Backup Mode. The switch parameter table
will be updated immediately.
S3 REVERT
Sets the backup unit for Revertive Backup Mode. The switch parameter table will be
updated immediately.
<BACKUP> MODE CONFIGURATION
BACKUP 1 <BACKUP> MODE: MANUAL
<MANUAL> <NON-REV> <REVERT> <RETURN>