RCS20 M:N Redundancy Switch Revision 15
User Interfaces MN-RCS20 and CD-RCS20
4–34
4.3.2.5 REMOTE PORT CONFIGURATION
This screen displays the Remote Port Baud Rate, the Remote Port Address, and the Terminal Emulation
Type, and allows the user to cycle to Subscreens to change the configurations. The baud rate may be
any of the following:
115200 57600 38400 19200 9600 4800 2400 1200
The Remote Port Address may be a value from 32 to 255, and is entered from the keypad. The Remote
Port Protocol may be one of the following:
• RLLP
• 2400
1. Press <BAUD> to cycle to the REMOTE PORT BAUD RATE CONFIGURATION Subscreen to
change the baud rate.
2. Press <ADDR> to cycle to the REMOTE PORT ADDRESS Subscreen to change the address.
3. Press <PROTOCOL> to cycle to the REMOTE PORT PROTOCOL CONFIGURATION
Subscreen to change the protocol type.
4. Press <CLR> to abort programming (no switch parameters changed).
Key Label Function
S1 BAUD
Press to cycle to the REMOTE PORT BAUD RATE CONFIGURATION
Subscreen.
S2 ADDR Press to cycle to the REMOTE PORT ADDRESS Subscreen.
S3 PROTOCOL Press to cycle to the REMOTE PORT PROTOCOL CONFIGURATION Subscreen.
S4 NEXT Press to cycle to the next screen.
Numeric Keypad ---
Press <CLR> to abort programming (no switch parameters changed).
REMOTE PORT CONFIGURATION
RCU20 REMOTE PORT BAUD RATE : 1200
RCU20 REMOTE PORT ADDRESS : 32
RCU20 REMOTE PORT PROTOCOL : RLLP
BAUD ADDR PROTOCOL NEXT