THIS DOCUMENT IS THE PROPERTY OF XICOM TECHNOLOGY. REPRODUCTION OR RELEASE WITHOUT EXPRESS PERMISSION IS STRICTLY PROHIBITED.
XTRD-400K, 400W, SNG
Document No. 305-0062-301 REV C Page 7 of 10
4.0 ENVIRONMENTAL
4.1 Non-operating
4.1.1 Temperature, non-operating -50 to +70 C
4.1.2 Shock, Vibration Normal transportation
4.2 Operating
4.2.1 Temperature -10 to +50 C
4.2.2 Humidity Up to 95%, non-condensing
4.2.3 Altitude, operating 0 to 10,000 ft
4.2.4 Cooling Requirements
4.2.4.1 100 CFM (170 m
3
/h
-1
) minimum required air flow.
4.2.4.2 Combined inlet and exhaust pressure loss (back pressure) to be less than 0.1” H
2
O
(24.9 Pa) @ CFM (170 m
3
/h
-1
).* (Contact Xicom Technology customer service for
technical assistance).
* NOTE: Pressure loss greater than 0.1” H
2
O (24.9 Pa) @ CFM (170 m
3
/h
-1
) will decrease air
flow (lower CFM) resulting in higher temperature operation and decreased life of
the HPA.
EAR EXPORT CONTROLLED: The information contained in this Manual refers or relates to a product that is subject
to the U.S. Export Administration Regulations (EAR). Transfer of data herein by any means to a Foreign Person,
whether in the U.S. or abroad, may require an export license from the U.S. Department of Commerce.