IMPORTANT NOTE: The information contained in this document supersedes all previously
published information regarding this product. Product specifications are subject to change
without prior notice.
Part Number MN/KPA.IOM Revision 1
KPA
Ku-Band Indoor Solid-State Power Amplifier Series
Installation and Operation Manual
Vista de página 0
1 2 3 4 5 6 ... 127 128

Resumo do Conteúdo

Página 1

IMPORTANT NOTE: The information contained in this document supersedes all previously published information regarding this product. Product specifica

Página 2

KPA Ku-Band Indoor Solid-State Power Amplifier Revision 1 Table of Contents MN/KPA.IOM vi 6.5.4.4 Status pages ...

Página 3 - Errata A

KPA Ku-Band Indoor Solid-State Power Amplifier Revision 1 Appendix C MN/KPA.IOM C–4 C.5.2 Target Address Up to 9,999 devices can be uni

Página 4

KPA Ku-Band Indoor Solid-State Power Amplifier Revision 1 Appendix C MN/KPA.IOM C–5 2. From Target-to-Controller, the only permitted va

Página 5 - October 29, 2010

KPA Ku-Band Indoor Solid-State Power Amplifier Revision 1 Appendix C MN/KPA.IOM C–6 C.5.7 End of Packet Controller-to-Target: This is t

Página 6

KPA Ku-Band Indoor Solid-State Power Amplifier Revision 1 Appendix C MN/KPA.IOM C–7 C.6 Remote Control Using FW Version 2.X.X and High

Página 7 - Table of Contents

KPA Ku-Band Indoor Solid-State Power Amplifier Revision 1 Appendix C MN/KPA.IOM C–8 C.6.1 Remote Commands and Queries (FW Version 2.X.X

Página 8

KPA Ku-Band Indoor Solid-State Power Amplifier Revision 1 Appendix C MN/KPA.IOM C–9 Parameter Type Command (Instr Code and Qualifier) Ar

Página 9

KPA Ku-Band Indoor Solid-State Power Amplifier Revision 1 Appendix C MN/KPA.IOM C–10 Parameter Type Command (Instr Code and Qualifier) A

Página 10

KPA Ku-Band Indoor Solid-State Power Amplifier Revision 1 Appendix C MN/KPA.IOM C–11 Parameter Type Command (Instr Code and Qualifier) A

Página 11 - Figures

KPA Ku-Band Indoor Solid-State Power Amplifier Revision 1 Appendix C MN/KPA.IOM C–12 Parameter Type Command (Instr Code and Qualifier) A

Página 12

KPA Ku-Band Indoor Solid-State Power Amplifier Revision 1 Appendix C MN/KPA.IOM C–13 Parameter Type Command (Instr Code and Qualifier) A

Página 13 - PREFACE

KPA Ku-Band Indoor Solid-State Power Amplifier Revision 1 Table of Contents MN/KPA.IOM vii C.7 Remote Control Using Firmware Version 1.X.X (OLD)

Página 14 - Cautions and Warnings

KPA Ku-Band Indoor Solid-State Power Amplifier Revision 1 Appendix C MN/KPA.IOM C–14 Parameter Type Command (Instr Code and Qualifier) A

Página 15 - IMPORTANT

KPA Ku-Band Indoor Solid-State Power Amplifier Revision 1 Appendix C MN/KPA.IOM C–15 Parameter Type Command (Instr Code and Qualifier) A

Página 16 - Limitations of Warranty

KPA Ku-Band Indoor Solid-State Power Amplifier Revision 1 Appendix C MN/KPA.IOM C–16 Parameter Type Command (Instr Code and Qualifier) A

Página 17 - Exclusive Remedies

KPA Ku-Band Indoor Solid-State Power Amplifier Revision 1 Appendix C MN/KPA.IOM C–17 C.7 Remote Control Using Firmware Version 1.X.X (O

Página 18 - Online Customer Support

KPA Ku-Band Indoor Solid-State Power Amplifier Revision 1 Appendix C MN/KPA.IOM C–18 C.7.1 Old Utility Commands Time Set Time: Confirma

Página 19 - Chapter 1. INTRODUCTION

KPA Ku-Band Indoor Solid-State Power Amplifier Revision 1 Appendix C MN/KPA.IOM C–19 Equipment Type Retrieve Equipment Type: Confirmati

Página 20 - 1.2 Functional Description

KPA Ku-Band Indoor Solid-State Power Amplifier Revision 1 Appendix C MN/KPA.IOM C–20 C.7.2 Old Configuration Commands Amplifier On/OFF

Página 21 - Introduction MN/KPA.IOM

KPA Ku-Band Indoor Solid-State Power Amplifier Revision 1 Appendix C MN/KPA.IOM C–21 C.7.3 Old Operating Mode Commands Note: There are

Página 22

KPA Ku-Band Indoor Solid-State Power Amplifier Revision 1 Appendix C MN/KPA.IOM C–22 C.7.4 Old Status Commands Configuration Status Co

Página 23 - 1.3 KPA Specifications

KPA Ku-Band Indoor Solid-State Power Amplifier Revision 1 Appendix C MN/KPA.IOM C–23 FET Status KPA-040 FET Status: Confirmation: <D

Página 24

KPA Ku-Band Indoor Solid-State Power Amplifier Revision 1 Table of Contents MN/KPA.IOM viii This page is deliberately bla

Página 25

KPA Ku-Band Indoor Solid-State Power Amplifier Revision 1 Appendix C MN/KPA.IOM C–24 Utility Status Utility Status: Confirmation: <

Página 26

KPA Ku-Band Indoor Solid-State Power Amplifier Revision 1 Appendix C MN/KPA.IOM C–25 Alarm Status KPA-080 KPA-100 Alarm Status: Confirm

Página 27 - 1.3.5 Dimensional Envelopes

KPA Ku-Band Indoor Solid-State Power Amplifier Revision 1 Appendix C MN/KPA.IOM C–26 Packed Maintenance Status Packed Maint Status: Conf

Página 28

KPA Ku-Band Indoor Solid-State Power Amplifier Revision 1 Appendix C MN/KPA.IOM C–27 Packed FET Status KPA-080 KPA-100 Packed FET Statu

Página 29 - Chapter 2. INSTALLATION

KPA Ku-Band Indoor Solid-State Power Amplifier Revision 1 Appendix C MN/KPA.IOM C–28 Packed Utility Status Packed Utility Status: Confi

Página 30 - 2.2 Rack Mounting the KPA

KPA Ku-Band Indoor Solid-State Power Amplifier Revision 1 Appendix C MN/KPA.IOM C–29 C.7.6 Error Processing The following Error Respons

Página 31 - Installation MN/KPA.IOM

KPA Ku-Band Indoor Solid-State Power Amplifier Revision 1 Appendix C MN/KPA.IOM C–30 Notes:

Página 32

METRIC CONVERSIONS Units of Length Unit Centimeter Inch Foot Yard Mile Meter Kilometer Millimeter 1 centimeter — 0.3937 0.03281 0.01094

Página 33 - PINOUTS

2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 • 333 • 2200 PHONE 480 • 333 • 2161 FAX

Página 34

ix PREFACE About this Manual This manual provides installation and operation information for the Comtech EF Data family of Ku-Band Indoor Solid-St

Página 35 - 3.2.2 J2 RF OUT Connector

KPA Ku-Band Indoor Solid-State Power Amplifier Revision 1 Preface MN/KPA.IOM x references apply to the MIL-STD-188-114A electrical characteristics f

Página 36 - 3.3 Utility Connections

KPA Ku-Band Indoor Solid-State Power Amplifier Revision 1 Preface MN/KPA.IOM xi Electrical Safety and Compliance Electromagnetic Compatibility (EMC)

Página 37

KPA Ku-Band Indoor Solid-State Power Amplifier Revision 1 Preface MN/KPA.IOM xii International Symbols Symbol Definition Symbol Definition Alter

Página 38

KPA Ku-Band Indoor Solid-State Power Amplifier Revision 1 Preface MN/KPA.IOM xiii The warranty does not cover replacement or repair necessitated by

Página 39 - 3.3.7 J6 COM 1 Connector

KPA Ku-Band Indoor Solid-State Power Amplifier Revision 1 Preface MN/KPA.IOM xiv Customer Support Contact the Comtech EF Data Customer Support Depar

Página 40

1–1 Chapter 1. INTRODUCTION 1.1 Overview The Comtech EF Data Ku-Band Solid-State Power Amplifier (KPA) family of products, shown in Figure 1-1, is a

Página 42 - Flash Upgrading MN/KPA.IOM

Ku-Band Solid-State Power Amplifier Revision 1 Introduction MN/KPA.IOM 1–2 1.2 Functional Description Each KPA ISSPA is constructed with highly re

Página 43

Ku-Band Solid-State Power Amplifier Revision 1 Introduction MN/KPA.IOM 1–3 Figure 1-2. KPA-020IN/-040 Block Diagram

Página 44

Ku-Band Solid-State Power Amplifier Revision 1 Introduction MN/KPA.IOM 1–4 Figure 1-3. KPA-080/-100 Block Di

Página 45 - OPERATION

Ku-Band Solid-State Power Amplifier Revision 1 Introduction MN/KPA.IOM 1–5 1.3 KPA Specifications 1.3.1 KPA-020IN Specifications Parameters Spec

Página 46 - 5.1.2 LED Indicators

Ku-Band Solid-State Power Amplifier Revision 1 Introduction MN/KPA.IOM 1–6 1.3.2 KPA-040 Specifications Parameters Specifications Input Level 10

Página 47 - 5.1.3 Keypad

Ku-Band Solid-State Power Amplifier Revision 1 Introduction MN/KPA.IOM 1–7 1.3.3 KPA-080 Specifications Parameters Specifications Input Impedance

Página 48 - 5.2 Opening Screen

Ku-Band Solid-State Power Amplifier Revision 1 Introduction MN/KPA.IOM 1–8 1.3.4 KPA-100 Specifications Parameters Specifications Input Level -10

Página 49 - 5.3 SELECT: (Main) Menu

Ku-Band Solid-State Power Amplifier Revision 1 Introduction MN/KPA.IOM 1–9 1.3.5 Dimensional Envelopes Figure 1-4. KPA-020IN Dimensional Envelo

Página 50 - ◄ ► arrows keys, then press

Ku-Band Solid-State Power Amplifier Revision 1 Introduction MN/KPA.IOM 1–10 Figure 1-5. KPA-040/-080/-100 Dimensional Envelope (Shown with Optiona

Página 51

2–1 Chapter 2. INSTALLATION 2.1 Unpacking and Inspection The KPA ISSPA and its Installation and Operation Manual are packaged and shipped in a pre-fo

Página 52

ER-KPA-EA1 THIS DOCUMENT IS NOT SUBJECT TO REVISION/UPDATE! PLM CO C-0027379 Page 1 of 2 Errata A Comtech EF Data Documentation Update

Página 53

KPA Ku-Band Indoor Solid State Power Amplifier Revision 1 Installation MN/KPA.IOM 2–2 2.2 Rack Mounting the KPA The KPA is designed to be rack-moun

Página 54 - 5.3.1.2 CONFIG: Amp

KPA Ku-Band Indoor Solid State Power Amplifier Revision 1 Installation MN/KPA.IOM 2–3 Figure 2-1. Installation of

Página 55

KPA Ku-Band Indoor Solid State Power Amplifier Revision 1 Installation MN/KPA.IOM 2–4 Notes:

Página 56

3–1 KPA-020IN Unit KPA-040/-080/-100 Units Chapter 3. CONNECTORS AND PINOUTS 3.1 Connector Overview The KPA ISSPA rear panel conn

Página 57 - 5.3.2 SELECT: Monitor

KPA Ku-Band Indoor Solid-State Power Amplifier Revision 1 Connectors and Pinouts MN/KPA.IOM 3–2 Table 3-1. KPA Interface Connectors Summary Connecto

Página 58 - 5.3.2.2 MONITOR: Stored

KPA Ku-Band Indoor Solid-State Power Amplifier Revision 1 Connectors and Pinouts MN/KPA.IOM 3–3 KPA-020IN Unit KPA-040/-080/-100 Units 3.2 RF Co

Página 59

KPA Ku-Band Indoor Solid-State Power Amplifier Revision 1 Connectors and Pinouts MN/KPA.IOM 3–4 3.3 Utility Connections 3.3.1 Sample Port Connect

Página 60 - 5.3.3.3 UTILITY: PowerMon

KPA Ku-Band Indoor Solid-State Power Amplifier Revision 1 Connectors and Pinouts MN/KPA.IOM 3–5 3.3.3 J5 DISCRETE CONTROL Connector The J5 DISCRETE

Página 61 - 5.3.3.5 UTILITY: RefOsc

KPA Ku-Band Indoor Solid-State Power Amplifier Revision 1 Connectors and Pinouts MN/KPA.IOM 3–6 Table 3-4. J5 DISCRETE CONTROL Connector Pinout (1:

Página 62 - 5.3.4 SELECT: Front Panel

KPA Ku-Band Indoor Solid-State Power Amplifier Revision 1 Connectors and Pinouts MN/KPA.IOM 3–7 3.3.6 J7 RF SWITCH Connector The J7 RF SWITCH conn

Página 63 - MANAGEMENT

ErrataAforMN/KPA.IOMRev1 AddTPEandTPSCommands/QueriestoAppendixC ER-KPA-EA1 THIS DOCUMENT IS NOT SUBJECT TO REVISION/UPDATE! PLM CO

Página 64

KPA Ku-Band Indoor Solid-State Power Amplifier Revision 1 Connectors and Pinouts MN/KPA.IOM 3–8 3.4 Power / Ground Connections 3.4.1 Alternating C

Página 65 - 6.4 Telnet Interface

4–1 Chapter 4. FLASH UPGRADING 4.1 Flash Upgrading via Internet The KPA ISSPAs use ‘Flash memory’ technology internally, which makes upgrading the fi

Página 66

KPA Ku-Band Indoor Solid-State Power Amplifier Revision 1 Flash Upgrading MN/KPA.IOM 4–2 4.2 Ethernet FTP Upload Procedure Follow the steps provide

Página 67 - 6.5.3 Web Server Menu Tree

KPA Ku-Band Indoor Solid-State Power Amplifier Revision 1 Flash Upgrading MN/KPA.IOM 4–3 3 (cont) About Firmware Numbers, File Versions, and Formats

Página 68 - 6.5.4.1 Home pages

KPA Ku-Band Indoor Solid-State Power Amplifier Revision 1 Flash Upgrading MN/KPA.IOM 4–4 10 Verify the file transfer. a) The M&C PC should repo

Página 69

5–1 Original (Obsolete) Front Panel Layout Current Front Panel Layout LED Indicators Keypad Liquid Crystal Diode (LCD) Display Vacuum

Página 70 - 6.5.4.2 Admin pages

KPA Ku-Band Indoor Solid-State Power Amplifier Revision 1 Front Panel Operation MN/KPA.IOM 5–2 5.1.1 Startup Checklist The user should always perfo

Página 71

KPA Ku-Band Indoor Solid-State Power Amplifier Revision 1 Front Panel Operation MN/KPA.IOM 5–3 5.1.3 Keypad As the manufacturing process of the KPA

Página 72 - 6.5.4.2.2 Admin

KPA Ku-Band Indoor Solid-State Power Amplifier Revision 1 Front Panel Operation MN/KPA.IOM 5–4 5.1.4 Front Panel Display As the manufacturing proce

Página 73 - Amplifier

KPA Ku-Band Indoor Solid-State Power Amplifier Revision 1 Front Panel Operation MN/KPA.IOM 5–5 5.3 SELECT: (Main) Menu SELECT: Config Monitor Uti

Página 74 - Alarm Mask

Copyright © Comtech EF Data, 2010. All rights reserved. Printed in the USA. Comtech EF Data, 2114 West 7th Street, Tempe, Arizona 85281 USA, 480.333.

Página 75 - [Change Offsets] as

KPA Ku-Band Indoor Solid-State Power Amplifier Revision 1 Front Panel Operation MN/KPA.IOM 5–6 Use the ◄ ► arrow keys to select from the choices sho

Página 76

KPA Ku-Band Indoor Solid-State Power Amplifier Revision 1 Front Panel Operation MN/KPA.IOM 5–7 If Serial Config: Interface is selected: M&C Bus

Página 77 - Redundancy Mode

KPA Ku-Band Indoor Solid-State Power Amplifier Revision 1 Front Panel Operation MN/KPA.IOM 5–8 Select the parameter to configure – Gateway, Address,

Página 78 - 6.5.4.4 Status pages

KPA Ku-Band Indoor Solid-State Power Amplifier Revision 1 Front Panel Operation MN/KPA.IOM 5–9 The user may view or edit the SNMP Write Community st

Página 79

KPA Ku-Band Indoor Solid-State Power Amplifier Revision 1 Front Panel Operation MN/KPA.IOM 5–10 5.3.1.2 CONFIG: Amp Amp: Attenuation State Mut

Página 80

KPA Ku-Band Indoor Solid-State Power Amplifier Revision 1 Front Panel Operation MN/KPA.IOM 5–11 Note: This command is valid only in Remote Æ Local m

Página 81 - TROUBLESHOOTING

KPA Ku-Band Indoor Solid-State Power Amplifier Revision 1 Front Panel Operation MN/KPA.IOM 5–12 If 1:2 Redundancy is recognized: Config: Auto/Manua

Página 82 - A.3 Troubleshooting

KPA Ku-Band Indoor Solid-State Power Amplifier Revision 1 Front Panel Operation MN/KPA.IOM 5–13 Use the ◄ ► arrows keys to select which Backup KPA i

Página 83 - A.3.1 Troubleshooting Guide

KPA Ku-Band Indoor Solid-State Power Amplifier Revision 1 Front Panel Operation MN/KPA.IOM 5–14 5.3.2.1 MONITOR: Faults Current Faults: Voltages

Página 84 - Appendix A MN/KPA.IOM

KPA Ku-Band Indoor Solid-State Power Amplifier Revision 1 Front Panel Operation MN/KPA.IOM 5–15 If Clear-All is selected: Clear All Stored Events:

Página 85

This page is intentionally blank.

Página 86

KPA Ku-Band Indoor Solid-State Power Amplifier Revision 1 Front Panel Operation MN/KPA.IOM 5–16 5.3.3.1 UTILITY: Date/Time Edit Real-Time Clock:

Página 87 - OPERATIONS

KPA Ku-Band Indoor Solid-State Power Amplifier Revision 1 Front Panel Operation MN/KPA.IOM 5–17 5.3.3.4 UTILITY: Firmware IMPORTANT THESE MENUS ARE

Página 88 - Waveguide

KPA Ku-Band Indoor Solid-State Power Amplifier Revision 1 Front Panel Operation MN/KPA.IOM 5–18 numeral, then press ENT. The default Reference Frequ

Página 89 - Appendix B MN/KPA.IOM

6–1 Chapter 6. KPA ETHERNET MANAGEMENT 6.1 Overview IMPORTANT This chapter is not valid for KPA-020IN operation. The sections that follow describe fu

Página 90

KPA Ku-Band Indoor Solid-State Power Amplifier Revision 1 Ethernet Management MN/KPA.IOM 6–2 6.3.1 Management Information Base (MIB) Files MIB fil

Página 91

KPA Ku-Band Indoor Solid-State Power Amplifier Revision 1 Ethernet Management MN/KPA.IOM 6–3 6.4 Telnet Interface The KPA provides a Telnet interfa

Página 92

KPA Ku-Band Indoor Solid-State Power Amplifier Revision 1 Ethernet Management MN/KPA.IOM 6–4 Login and remote command execution via HyperTerminal co

Página 93

KPA Ku-Band Indoor Solid-State Power Amplifier Revision 1 Ethernet Management MN/KPA.IOM 6–5 Once the valid User name and Password are accepted, the

Página 94

KPA Ku-Band Indoor Solid-State Power Amplifier Revision 1 Ethernet Management MN/KPA.IOM 6–6 6.5.4.1 Home pages Select the Home or Support hyperlin

Página 95 - -1.75 dB

KPA Ku-Band Indoor Solid-State Power Amplifier Revision 1 Ethernet Management MN/KPA.IOM 6–7 6.5.4.1.2 Home | Support page Figur

Página 96 - +1.75 dB

iii Table of Contents TABLE OF CONTENTS ...

Página 97 - Appendix C. REMOTE CONTROL

KPA Ku-Band Indoor Solid-State Power Amplifier Revision 1 Ethernet Management MN/KPA.IOM 6–8 6.5.4.2 Admin pages The ‘Admin’ pages provide the mean

Página 98 - C.4 Basic Protocol

KPA Ku-Band Indoor Solid-State Power Amplifier Revision 1 Ethernet Management MN/KPA.IOM 6–9 System Account Access Information • Read/Write, Read O

Página 99 - C.5.1 Start of Packet

KPA Ku-Band Indoor Solid-State Power Amplifier Revision 1 Ethernet Management MN/KPA.IOM 6–10 6.5.4.2.2 Admin | SNMP page Figure 6-4. Admin

Página 100 - C.5.4 Instruction Code

KPA Ku-Band Indoor Solid-State Power Amplifier Revision 1 Ethernet Management MN/KPA.IOM 6–11 6.5.4.3 Config (Configuration) pages The ‘Config’ pag

Página 101

KPA Ku-Band Indoor Solid-State Power Amplifier Revision 1 Ethernet Management MN/KPA.IOM 6–12 • Baud Rate: Use the drop-down menu to select the bau

Página 102 - C.5.7 End of Packet

KPA Ku-Band Indoor Solid-State Power Amplifier Revision 1 Ethernet Management MN/KPA.IOM 6–13 6.5.4.3.2 Config | Utility page Figure

Página 103 - C–7

KPA Ku-Band Indoor Solid-State Power Amplifier Revision 1 Ethernet Management MN/KPA.IOM 6–14 6.5.4.3.3 Config | Redundancy page IMPORTANT Comtech

Página 104 - C–8

KPA Ku-Band Indoor Solid-State Power Amplifier Revision 1 Ethernet Management MN/KPA.IOM 6–15 Redundancy Mode This read-only section provides the fo

Página 105 - C–9

KPA Ku-Band Indoor Solid-State Power Amplifier Revision 1 Ethernet Management MN/KPA.IOM 6–16 6.5.4.4 Status pages The ‘Status’ pages provide the u

Página 106 - C–10

KPA Ku-Band Indoor Solid-State Power Amplifier Revision 1 Ethernet Management MN/KPA.IOM 6–17 Once the desired settings have been entered, click [Su

Página 107 - C–11

KPA Ku-Band Indoor Solid-State Power Amplifier Revision 1 Table of Contents MN/KPA.IOM iv 1.3.4 KPA-100 Specifications ...

Página 108 - C–12

KPA Ku-Band Indoor Solid-State Power Amplifier Revision 1 Ethernet Management MN/KPA.IOM 6–18 6.5.4.4.3 Status | FETs page Figure 6-1

Página 109 - C–13

A–1 Appendix A. MAINTENANCE AND TROUBLESHOOTING A.1 Introduction Information about the KPA’s operational features and overall functionality is provi

Página 110 - C–14

KPA Ku-Band Indoor Solid-State Power Amplifier Revision 1 Appendix A MN/KPA.IOM A–2 A.2 Maintenance Testing Note the following: • The KPA-080 is a

Página 111 - C–15

KPA Ku-Band Indoor Solid-State Power Amplifier Revision 1 Appendix A MN/KPA.IOM A–3 A.3.1 Troubleshooting Guide Issue Possible Cause(s) Solution(

Página 112 - C–16

KPA Ku-Band Indoor Solid-State Power Amplifier Revision 1 Appendix A MN/KPA.IOM A–4 Issue Possible Cause(s) Solution(s) No RF output or ≤ output

Página 113 - C–17

KPA Ku-Band Indoor Solid-State Power Amplifier Revision 1 Appendix A MN/KPA.IOM A–5 Issue Possible Cause(s) Solution(s) Amplifier Temperature Fau

Página 114 - C.7.1 Old Utility Commands

KPA Ku-Band Indoor Solid-State Power Amplifier Revision 1 Appendix A MN/KPA.IOM A–6 Notes:

Página 115 - C–19

B–1 Appendix B. KPA REDUNDANT OPERATIONS B.1 Introduction IMPORTANT Comtech EF Data’s KPA family of ISSPAs are designed to automatically sense and c

Página 116 - C–20

KPA Ku-Band Indoor Solid-State Power Amplifier Revision 1 Appendix B MN/KPA.IOM B–2 B.2 Redundancy Operation Figure B-1. 1:1 Redundancy Block Diagr

Página 117 - C–21

KPA Ku-Band Indoor Solid-State Power Amplifier Revision 1 Appendix B MN/KPA.IOM B–3 they are not shown in this manual. Contact Comtech EF Data for 1

Página 118 - C.7.4 Old Status Commands

KPA Ku-Band Indoor Solid-State Power Amplifier Revision 1 Table of Contents MN/KPA.IOM v 5.3.1.1 CONFIG: Remote (Remote Control) ...

Página 119 - C–23

KPA Ku-Band Indoor Solid-State Power Amplifier Revision 1 Appendix B MN/KPA.IOM B–4 B.3.1 Redundancy Kit Control Cabling For either a 1:1 or a 1:2

Página 120 - C–24

KPA Ku-Band Indoor Solid-State Power Amplifier Revision 1 Appendix B MN/KPA.IOM B–5 This page is intentionally blank.

Página 121 - C–25

KPA Ku-Band Indoor Solid-State Power Amplifier Revision 1 Appendix B MN/KPA.IOM B–6 Table B-1. KPA Redundancy Kits – Parts List ITEM CEFD PART NO.

Página 122 - C–26

KPA Ku-Band Indoor Solid-State Power Amplifier Revision 1 Appendix B MN/KPA.IOM B–7 Figure B-4. 1:1 Redundancy K

Página 123 - C–27

KPA Ku-Band Indoor Solid-State Power Amplifier Revision 1 Appendix B MN/KPA.IOM B–8 B.4 Gain Equalization of Redundant Units To equalize the gain

Página 124 - C.7.5 Old Stored Alarms

KPA Ku-Band Indoor Solid-State Power Amplifier Revision 1 Appendix B MN/KPA.IOM B–9 B.4.1 Case Examples Case 1. Backup Å Online unit(s) 1. Ensure

Página 125 - C.7.8 Time-Outs

KPA Ku-Band Indoor Solid-State Power Amplifier Revision 1 Appendix B MN/KPA.IOM B–10 Case 2. Backup Æ Online unit(s) 1. With the Backup Unit force

Página 126 - C–30

C–1 Appendix C. REMOTE CONTROL C.1 Overview This appendix describes the protocol and message command set for remote monitor and control of the KPA

Página 127 - Units of Weight

KPA Ku-Band Indoor Solid-State Power Amplifier Revision 1 Appendix C MN/KPA.IOM C–2 All of the Targets receive the packet, but only one

Página 128 - • 333 • 2161 FAX

KPA Ku-Band Indoor Solid-State Power Amplifier Revision 1 Appendix C MN/KPA.IOM C–3 C.5 Packet Structure Controller-to-Target Start of

Comentários a estes Manuais