Comtech EF Data Vipersat CDD-564L Especificações Página 56

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 254
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 55
CDD-562L/564 Demodulator with IP Module Revision 2
Rear Panel Connections MN/CDD564L.IOM
3–10
3.3.3.2 DC Operation – Replacing Fuses
The CDD-56X uses two 5mm x 20mm Slow-blow fuses – one each for line and neutral
connections. The fuses are contained within a fuse holder that is press-fit into the body of the DC
power module (located on the rear panel, Figure 3-8).
Feature Description
1 Hinged Flap
2 Press-fit Fuse Holder
3 Fuse (2X)
Figure 3-8. Replacing CDD-56X DC Fuses
To replace the fuse(s):
DISCONNECT THE POWER SUPPLY BEFORE PROCEEDING!
First, using a flat-bladed screwdriver, use the slot to pry open and swing back the
hinged flap.
Next, extract the press-fit fuse holder:
o Using the screwdriver, disengage the fuse holder outward from the DC power module.
o Using your fingers, pull the holder straight out of the module.
Then, remove and replace the T8A (8 Amp) fuses as needed.
FORCONTINUEDOPERATORSAFETY,ALWAYSREPLACETHEFUSESWITHTHE
CORRECTTYPEANDRATING.
Finally, re-seat the fuse holder into the DC power module, and close the protective flap.
Vista de página 55
1 2 ... 51 52 53 54 55 56 57 58 59 60 61 ... 253 254

Comentários a estes Manuais

Sem comentários