CDM-800 Gateway Router Revision 1
Ethernet-based Remote Product Management MN-CDM800
5–46
o Then,usethetop(Save)SelectLocationdropdowntoselect1through10.
o Finally,click[SaveConfiguration]tostoretheconfigurationsettings.
• Toload(recall)aconfigurationset:
o First,usethebottom(Load)SelectLocationdropdowntoselect1through10.
o Then,click[L
oadConfigur
ation]torecalltheselectedconfigurationsettings.
BERT Config
(WhereBERTistheacronymforBitErrorRateTest)Usethedrop‐downmenusto:
• ConfiguretheTxBERTStateasOnorOff.
• ConfiguretheTxorRxBERTPatternas2^23‐1(2
23
‐1)or2047.
• SetErrorInsert(ion)aseitherOffor10E‐3.
Click[Submit]tosavetheBERTsettingsandexecutethetest.
OncetheTxBERTisexecuted,theentireoutboundcarriertransmitsaBERTpattern.
AllIPcommunicationsarehaltedduringthistest.
Notealso th
atth
eRxBERTStateforthe CDM‐840RemoteRoutermust beenabled
toproperlyreceiveandmonitortheBERTpattern.
Redundancy
• CurrentRedundancyState(read‐only)–StatusislistedasOnLineorOffLine.
• OfflineUnitStatus(read‐only)–Thisindicatesthestatusoftheofflineunit.
If the unit is not connected to a redundancy switch, the status is listed as No_1F1.
Otherwise,itsstatusislistedasOnLi
neorOffLi
ne.
Iftheunitispartofa1:1or1:NredundantpairofCDM‐800s,andthisunitiscurrentlyOnLine,
click[ForceRedundancySwitch]tocausetheunittoswitchtostandby.