Vista de página 208
CDM-710 Broadcast Satellite Modem Revision 10
Remote Control MN/CDM710.IOM
A–47
Parameter
Type
Command
(Instruction
Code and
Qualifier)
Arguments
for Command
or Response
to Query
Description of Arguments
Response
to
Command
Query
(Instruction
Code and
Qualifier)
Response to Query
Software
Revision
N/A 5 bytes Query Only.
Unit returns the value of the internal software revision installed
in the unit, in the form: Boot:X.X.X Bulk1:Y.Y.Y Bulk2: Z.Z.Z
Example: SWR=Boot:1.0.3 Bulk1:1.0.1 Bulk2:1.0.0
SWR?
SWR*
SWR#
SWR? SWR=Boot:X.X.X
Bulk1:Y.Y.Y
Bulk2:Z.Z.Z
Real-time
Clock Time
TIM= 6 bytes Command or Query.
A time in the form hhmmss, indicating the time from midnight,
where:
hh = hours (00 to 23)
mm = minutes (00 to 59)
ss = seconds (00 to 59)
Example: TIM=231259 (23 hours:12 minutes:59 seconds)
TIM=
TIM?
TIM*
TIM#
TIM? TIM=hhmmss
Temperature N/A 3 bytes Query Only.
Unit returns the value of the internal temperature, in the form of
sxxx (degrees C). Where s is the sign and and xxx is the number
of degrees.
Example: TMP=+026
TMP?
TMP*
TMP#
TMP? TMP=sxxx