Comtech EF Data UT-4514F Especificações Página 133

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
Vista de página 132
UT-4500-A Series Upconverters Revision 1
Appendix A MN-UT4500A
A–23
A.7.4.6 Terminal Status Change
The TSC_ command can be used to determine if the status of the terminal has changed since it
was last polled. If any of the parameters listed in the RCS or RUS commands have changed as a
result of user front panel operations or remote operations or if any new fault condition occur
the TSC_ command will return YES. The TSC_ command will then continue to return YES until
any of the following commands are received: RCS_, RUS_, RAS_, PACRCS_, PACRUS_, or PACRAS.
Command
Details
Configuration Status:
<DEV/TSC_'cr’
Confirmation:
>DEV/TSC_nnn'cr''lf'] nnn=YES/NO
A.7.4.7 Packed Configuration Status
Configuration Status: <DEV/PACRCS_'cr'
Confirmation: >DEV/PACRCS_aaaabbbcdeffgghijkl'cr''lf']
where:
aaaa = # of 125kHz steps above base frequency
1
bbb = # of 0.25 dB steps above 0.00 dB
2
c = 1 if Transmitter ON, 0 if OFF, 2 if Cold
d = 1 if unit ONLINE, 0 if OFFLINE
e = 1 if Redundancy ON, else 0
ff = converter # (01-12,BU or 00 if e = 0)
gg = 00 if 'ff' is 00 (redundancy OFF)
gg = chain length (01-12) if 'ff' is BU
gg = XX if 'ff' = 01 - 12
h = A if Auto Mode, M if Manual
3
I = 1 if Cold Start Enabled, else 0
j = 1 if Auto recovery enabled, else 0
k = 1 if an Ext. Ref is present, else 0
l = 1 if Remote Mode, 0 if Local Mode
Notes:
1. If the converter is 1 kHz step size, this will be the number of 1 kHz steps above the base
frequency
2. If the converter is 0.1 -dB step size, this will be the number of 0.1 -dB steps above the
base frequency
3. If it is a backup converter, it is always ‘A’
Vista de página 132
1 2 ... 128 129 130 131 132 133 134 135 136 137 138 ... 161 162

Comentários a estes Manuais

Sem comentários