Comtech EF Data KST-2000A Especificações Página 176

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 182
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 175
Ku-Band Satellite Transceiver Revision 9
FSK Remote Control Commands MN/KST2000AB.IOM
E-24
Parameter
Type
Command
(Instruction
Code and
qualifier)
Arguments for
Command or
Response to
Query
Description of arguments
(note that all arguments are ASCII numeric codes, that is, ASCII
codes between 48 and 57)
Response to Command (target to
controller)
Query
(Instruction
Code and
qualifier)
Clear Latched Up
Converter Faults
ULR= None Command only.
<add/ULR=’cr’
>add/ULR=’cr’’lf’
ULR= (message ok)
ULR? (received ok, but invalid arguments
found)
ULR* (message ok, but not permitted in
current mode)
n.a.
Clear Latched
Down Converter
Faults
DLR= None Command only.
<add/DLR=’cr’
>add/DLR=’cr’’lf’
DLR= (message ok)
DLR? (received ok, but invalid arguments
found)
DLR* (message ok, but not permitted in
current mode)
n.a.
Set Receive Band SRB= 1 byte Command/Query.
<add/SRB=n’cr’
>add/SRB=’cr’’lf’
<add/SRB?’cr’
>add/SRB=n’cr’’lf’
Where n = A, B, or C the receive band.
SRB= (message ok)
SRB? (received ok, but invalid arguments
found)
SRB* (message ok, but not permitted in
current mode)
SRB?