CDM-Qx Satellite Modem Revision 5
Front Panel Operation MN/CDMQx.IOM
5–10
5.6.1.1 (ConfigRemote) – REMOTE CONTROL
Select Local, Serial, or Ethernet using the
( )arrow keys, then press ENT.
If Local is selected then remote control will be disabled. Remote monitoring is still
possible.
(ConfigRemoteSerial)
If Serial is selected:
(ConfigRemoteSerialInterface)
If Interface is selected:
Select RS232, RS485-2W (2-wire), or RS485-4W (4-wire), using the arrow keys,
then press ENT.
At this point the user will be further prompted to enter the bus address.
If RS232 is selected, the following menu is displayed:
Remote Control Entry: Local
Serial Ethernet ( ,ENT)
Remote Serial Con
f
ig:
Interface Baudrate ( ,ENT)
M&C Serial Interface: RS232
RS485-2W RS485-4W ( ,ENT)
In RS-232 Mode, Serial Bus
Base Address is fixed @ 0000