C5/K1/K3C5/K1/K3C5/K1/K3C5/K1/K3Integrated Satellite Terminal SystemIntegrated Satellite Terminal SystemIntegrated Satellite Terminal SystemIntegrated
Table of Contents C5/K1/K3 Integrated Satellite Terminal Systemvi Rev. 02.1.5.3 Phase Noise ...
Installation C5/K1/K3 Integrated Satellite Terminal System3–4 Rev. 0Tools RequiredNote: Equivalent substitutes may be used for listed items.Qty. Descr
C5/K1/K3 Integrated Satellite Terminal System InstallationRev. 0 3–5This page is intentionally left blank.
Installation C5/K1/K3 Integrated Satellite Terminal System3–6 Rev. 03.3 Satellite Terminal System Installation3.3.1 IDU InstallationRefer to Figure 3
C5/K1/K3 Integrated Satellite Terminal System InstallationRev. 0 3–7EQUIPMENTRACKSCREWWITHFLAT WASHERBRACKETBOLTSMOUNTINGBRACKETIDUFigure 3-1. IDU In
Installation C5/K1/K3 Integrated Satellite Terminal System3–8 Rev. 03.3.2 ODU Installation3.3.2.1 C-Band ODU Installation1. Install LNA with TRF to
C5/K1/K3 Integrated Satellite Terminal System InstallationRev. 0 3–912345678910TIGHTEN BOLTS PER ILLUSTRATED SEQUENCEFigure 3-2. LNA Installation3. C
Installation C5/K1/K3 Integrated Satellite Terminal System3–10 Rev. 0OMT(REFERENCE ONLY)TX CABLETX CABLETX CABLERX CABLERX CABLERX CABLEMOUNTING KITU-
C5/K1/K3 Integrated Satellite Terminal System InstallationRev. 0 3–113.3.2.2 Ku-Band ODU InstallationRefer to Figure 3-4.1. Install ODU as follows:a.
Installation C5/K1/K3 Integrated Satellite Terminal System3–12 Rev. 0OMT(REFERENCE ONLY)KU-BANDODUTX CABLETX CABLERX CABLERX CABLEMOUNTING KITU-BOLT (
C5/K1/K3 Integrated Satellite Terminal System InstallationRev. 0 3–133.3.2.3 K1/K3 ODU 90 Rotation CheckRefer to Figure 3-5.1. Loosen ring bracke
C5/K1/K3 Integrated Satellite Terminal System Table of ContentsRev. 0 vii2.3.4 Performance with Noise, 1544 kbit/s, and Sequential Decoder...
Installation C5/K1/K3 Integrated Satellite Terminal System3–14 Rev. 0This page is intentionally left blank.
C5/K1/K3 Integrated Satellite Terminal System InstallationRev. 0 3–153.4 External IDU ConnectionsWhen a breakout panel, such as the UB-300, is not re
Installation C5/K1/K3 Integrated Satellite Terminal System3–16 Rev. 0J6REMOTEALARMSJ10FAULTJ7J9AUX 1RRTXXF/IF INPUTCP3CP1CP2//IIFFOOUUTTPPUUTTFigure 3
C5/K1/K3 Integrated Satellite Terminal System InstallationRev. 0 3–173.4.1 Remote Connector and Pinouts (J6)The remote connector is a 9-pin female D
Installation C5/K1/K3 Integrated Satellite Terminal System3–18 Rev. 03.4.2 Fault Connector and Pinouts (J7)The fault connector provides Form C contac
C5/K1/K3 Integrated Satellite Terminal System InstallationRev. 0 3–193.4.3 Data I/O Interface Connector (J8)The DATA I/O interface connector conducts
Installation C5/K1/K3 Integrated Satellite Terminal System3–20 Rev. 0Table 3-4. 25-Pin D Connector Pinouts25-Pin D ConnectorPin # EIA-422 EIA-232 V.3
C5/K1/K3 Integrated Satellite Terminal System InstallationRev. 0 3–21Note: The 50-pin connector requires a breakout panel for the externalconnections
Installation C5/K1/K3 Integrated Satellite Terminal System3–22 Rev. 0Table 3-6. EIA-449 MIL-188 114, 37-Pin Connector Pinouts37 EIA-422 37 EIA-4226RD
C5/K1/K3 Integrated Satellite Terminal System InstallationRev. 0 3–23Table 3-7. 34-Pin Winchester Connector Pinouts (V.35)34 V.35 34 V.35R RX Data A
Table of Contents C5/K1/K3 Integrated Satellite Terminal Systemviii Rev. 03.2 Equipment Inspection...
Installation C5/K1/K3 Integrated Satellite Terminal System3–24 Rev. 03.4.3.1 Data I/O Interface Connector (J8) Removal/InstallationNote: The followin
C5/K1/K3 Integrated Satellite Terminal System InstallationRev. 0 3–253.4.3.1.1 Data I/O Connector (J8) RemovalRefer to Figure 3-10.1. (For Ribbon-Con
Installation C5/K1/K3 Integrated Satellite Terminal System3–26 Rev. 0For Ribbon-Configured ConnectorFor 50-Pin Connector with Overhead Interface Board
C5/K1/K3 Integrated Satellite Terminal System InstallationRev. 0 3–273.4.4 Auxiliary Connector and Pinouts (J9)AUX connection is a 9-pin female D con
Installation C5/K1/K3 Integrated Satellite Terminal System3–28 Rev. 03.4.5 Alarm (J10)The alarm interface connection is a 9-pin female D connector loc
C5/K1/K3 Integrated Satellite Terminal System InstallationRev. 0 3–293.5 IDU–ODU Interconnections3.5.1 C-Band (IDU-ODU) Interconnections (CP1, CP2, C
Installation C5/K1/K3 Integrated Satellite Terminal System3–30 Rev. 03.6 Power Entry3.6.1 AC Option (Standard)Input Power 300W maximum, 125W typicalI
Rev. 0 4–114Chapter 4. OPERATIONThis chapter describes the front panel operation of the modem, including the menus andtheir explanations, software con
Operation C5/K1/K3 Integrated Satellite Terminal System4–2 Rev. 0All functions are accessible at the front panel by entering one of six pre-defined Fu
C5/K1/K3 Integrated Satellite Terminal System OperationRev. 0 4–34.1.2 Front Panel KeypadThe front panel keypad permits local operation of the modem.
C5/K1/K3 Integrated Satellite Terminal System Table of ContentsRev. 0 ix4.1.3.10 Remote AUPC...
Operation C5/K1/K3 Integrated Satellite Terminal System4–4 Rev. 0SDT5200"TYPE"VER: 1.1.1FUNCTION SELECTCONFIGURATIONFUNCTION SELECTMONITOR(F
C5/K1/K3 Integrated Satellite Terminal System OperationRev. 0 4–54.1.3 Menu SystemNote: The Utility Factory Setup (Figure 4-20) menu is for EFData ser
Operation C5/K1/K3 Integrated Satellite Terminal System4–6 Rev. 0Press [$] or [%] to change the parameters. After the display represents the correctpa
C5/K1/K3 Integrated Satellite Terminal System OperationRev. 0 4–7This page is intentionally left blank.
Operation C5/K1/K3 Integrated Satellite Terminal System4–8 Rev. 0SDT5200 "TYPE"VER: X.X.XFUNCTION SELECTCONFIGURATIONCONFIGURATIONMODULATORT
C5/K1/K3 Integrated Satellite Terminal System OperationRev. 0 4–94.1.3.1 Configuration ModulatorRefer to Figure 4-4.TX-x/Type/Code Rate Transmit code
Operation C5/K1/K3 Integrated Satellite Terminal System4–10 Rev. 0TX POWER LEVEL C-Band - Programs the modulator output power level from+25.0 to +39.0
C5/K1/K3 Integrated Satellite Terminal System OperationRev. 0 4–11CARRIER MODE(Test Mode Configuration)Programs the modem for continuous wave mode. Fo
Operation C5/K1/K3 Integrated Satellite Terminal System4–12 Rev. 0SDT5200 "TYPE"VER: X.X.XFUNCTION SELECTCONFIGURATIONCONFIGURATIONDEMODULA
C5/K1/K3 Integrated Satellite Terminal System OperationRev. 0 4–134.1.3.2 Configuration DemodulatorRefer to Figure 4-5.RX-x /Type/Code Rate Receiver c
Table of Contents C5/K1/K3 Integrated Satellite Terminal Systemx Rev. 05.4 Demodulator...
Operation C5/K1/K3 Integrated Satellite Terminal System4–14 Rev. 0RF LOOPBACK Tunes the RX frequency to the satellite downlink frequency for theconfig
C5/K1/K3 Integrated Satellite Terminal System OperationRev. 0 4–15REACQUISITION Programs the sweep reacquisition mode time duration. This is thetime t
Operation C5/K1/K3 Integrated Satellite Terminal System4–16 Rev. 0SDT5200 "TYPE"VER: X.X.XFUNCTION SELECTCONFIGURATIONCONFIGURATIONINTERFACE
C5/K1/K3 Integrated Satellite Terminal System OperationRev. 0 4–17ASYNC TX BAUD110 2400150 4800300 9600600 192001200 38400RX ASYNC Overhead only.110 2
Operation C5/K1/K3 Integrated Satellite Terminal System4–18 Rev. 04.1.3.3 Configuration InterfaceRefer to Figure 4-6.TX CLOCK SOURCE Programs the cloc
C5/K1/K3 Integrated Satellite Terminal System OperationRev. 0 4–19BUFFER CLOCK Programs the interface buffer output clock to one of the followingmodes
Operation C5/K1/K3 Integrated Satellite Terminal System4–20 Rev. 0INTERFACE LOOPBACK(Test Mode Configuration)Programs the modem for Interface Loopback
C5/K1/K3 Integrated Satellite Terminal System OperationRev. 0 4–21RX DATA FAULTReceive data fault. Press [$] or [%] to select one of the followingmode
Operation C5/K1/K3 Integrated Satellite Terminal System4–22 Rev. 0ASYNC RX BAUD Programs the ASYNC overhead RX baud rate for 110 to 38400 bit/s.Upon e
C5/K1/K3 Integrated Satellite Terminal System OperationRev. 0 4–23This page is intentionally left blank.
C5/K1/K3 Integrated Satellite Terminal System Table of ContentsRev. 0 xiA.2.1.5 ASYNC Remote Operation ...
Operation C5/K1/K3 Integrated Satellite Terminal System4–24 Rev. 0SDT5200 "TYPE"VER: X.X.XFUNCTION SELECTCONFIGURATIONCONFIGURATIONLOCAL AUP
C5/K1/K3 Integrated Satellite Terminal System OperationRev. 0 4–254.1.3.4 Configuration Local AUPCRefer to Figure 4-7.AUPC ENABLE Programs the AUPC On
Operation C5/K1/K3 Integrated Satellite Terminal System4–26 Rev. 0TRACKING RATE Programs the maximum tracking rate of the AUPC.Maximum tracking rate c
C5/K1/K3 Integrated Satellite Terminal System OperationRev. 0 4–27This page is intentionally left blank.
Operation C5/K1/K3 Integrated Satellite Terminal System4–28 Rev. 0SDT5200 "TYPE"VER: X.X.XFUNCTION SELECTCONFIGURATIONCONFIGURATIONSAVECONFI
C5/K1/K3 Integrated Satellite Terminal System OperationRev. 0 4–294.1.3.5 Configuration SaveRefer to Figure 4-8.The Configuration Save menu allows pro
Operation C5/K1/K3 Integrated Satellite Terminal System4–30 Rev. 0SDT5200 "TYPE"VER: X.X.XFUNCTION SELECTMONITORRAW BERCORRECTEDBEREB/NO REC
C5/K1/K3 Integrated Satellite Terminal System OperationRev. 0 4–314.1.3.7 MonitorRefer to Figure 4-10.When the Monitor level is entered press ["]
Operation C5/K1/K3 Integrated Satellite Terminal System4–32 Rev. 0This page is intentionally left blank.
C5/K1/K3 Integrated Satellite Terminal System OperationRev. 0 4–334.1.3.8 Faults/AlarmsRefer to Figure 4-11.The Faults/Alarms menu is accessible from
Table of Contents C5/K1/K3 Integrated Satellite Terminal Systemxii Rev. 0INDEX ...
Operation C5/K1/K3 Integrated Satellite Terminal System4–34 Rev. 0SDT5200 "TYPE"VER: X.X.XFUNCTION SELECTFAULTS/ALARMSMODULATOR DEMODULATOR
C5/K1/K3 Integrated Satellite Terminal System OperationRev. 0 4–354.1.3.8.1 Modulator FaultsIF SYNTHESIZER Modulator IF synthesizer fault.DATA CLOCK S
Operation C5/K1/K3 Integrated Satellite Terminal System4–36 Rev. 04.1.3.8.4 Receive Interface FaultsBUFFER UNDERFLOW Buffer underflow alarm. Indicates
C5/K1/K3 Integrated Satellite Terminal System OperationRev. 0 4–37This page is intentionally left blank.
Operation C5/K1/K3 Integrated Satellite Terminal System4–38 Rev. 0SDT5200 "TYPE"VER: X.X.XFUNCTION SELECTSTOREDFLTS/ALMSMODULATOR x DEMODULA
C5/K1/K3 Integrated Satellite Terminal System OperationRev. 0 4–394.1.3.9 Stored Faults/AlarmsRefer to Figure 4-12.The modem stores the first 10 (Flt0
Operation C5/K1/K3 Integrated Satellite Terminal System4–40 Rev. 0SDT5200 "TYPE"VER: X.X.XFUNCTION SELECTREMOTE AUPCREMOTE AUPCCONFIGURATION
C5/K1/K3 Integrated Satellite Terminal System OperationRev. 0 4–414.1.3.10 Remote AUPCTo view or change the Remote AUPC functions, enter the Remote AU
Operation C5/K1/K3 Integrated Satellite Terminal System4–42 Rev. 0This page is intentionally left blank.
C5/K1/K3 Integrated Satellite Terminal System OperationRev. 0 4–434.1.3.11 UtilityThe Function Select Utility menu is divided into the following categ
C5/K1/K3 Integrated Satellite Terminal System Table of ContentsRev. 0 xiiiFiguresFigure 1-1. The C-Band (C5) System...
Operation C5/K1/K3 Integrated Satellite Terminal System4–44 Rev. 0SDT5200 "TYPE"VER: X.X.XFUNCTION SELECTUTILITYUTILITYMODULATORASSIGN TRANS
C5/K1/K3 Integrated Satellite Terminal System OperationRev. 0 4–454.1.3.11.1 Utility ModulatorRefer to Figure 4-15.UTILITY Displays single code/data r
Operation C5/K1/K3 Integrated Satellite Terminal System4–46 Rev. 0ODU FAULT ENABLE ODU Fault Enable selection. Select on or off.TX SYMBOL RATE Status
C5/K1/K3 Integrated Satellite Terminal System OperationRev. 0 4–47This page is intentionally left blank.
Operation C5/K1/K3 Integrated Satellite Terminal System4–48 Rev. 0SDT5200 "TYPE"VER: X.X.XFUNCTION SELECTUTILITYUTILITYDEMODULATORASSIGN REC
C5/K1/K3 Integrated Satellite Terminal System OperationRev. 0 4–494.1.3.11.2 Utility DemodulatorRefer to Figure 4-16.ASSIGN RECEIVERFILTERSReceive fil
Operation C5/K1/K3 Integrated Satellite Terminal System4–50 Rev. 0SDT5200 "TYPE"VER: X.X.XFUNCTION SELECTUTILITYUTILITYINTERFACETX OVERHEAD
C5/K1/K3 Integrated Satellite Terminal System OperationRev. 0 4–514.1.3.11.3 Utility InterfaceRefer to Figure 4-17.TX OVERHEAD TYPE Select NONE or ASY
Operation C5/K1/K3 Integrated Satellite Terminal System4–52 Rev. 0TX DATA PHASE TX data phase relationship. Use this option to select Normal or Invert
C5/K1/K3 Integrated Satellite Terminal System OperationRev. 0 4–53This page is intentionally left blank.
Table of Contents C5/K1/K3 Integrated Satellite Terminal Systemxiv Rev. 0Figure 4-25. EIA-422, EIA-232, or V.35 Master/Slave Clocking Diagram ...
Operation C5/K1/K3 Integrated Satellite Terminal System4–54 Rev. 0SDT5200 "TYPE"VER: X.X.XFUNCTION SELECTUTILITYUTILITYSYSTEMTIME: HH:MM:SS
C5/K1/K3 Integrated Satellite Terminal System OperationRev. 0 4–55ACCESS TOSUBMENUCONDITIONAL OROPTION-DEPENDENTParameter InformationKey:M&C FIRMW
Operation C5/K1/K3 Integrated Satellite Terminal System4–56 Rev. 04.1.3.11.4 Utility SystemRefer to Figure 4-18.TIME: HH:MM:SS AM/PMDATE: MM/DD/YYTime
C5/K1/K3 Integrated Satellite Terminal System OperationRev. 0 4–57TEST MODE STATUS Test mode status indicator. The following modem test points arelist
Operation C5/K1/K3 Integrated Satellite Terminal System4–58 Rev. 0SYSTEM WARM UP Displays status of warm-up as either:AUTO: 5 minutesMANUAL: 0 to 15 m
C5/K1/K3 Integrated Satellite Terminal System OperationRev. 0 4–59This page is intentionally left blank.
Operation C5/K1/K3 Integrated Satellite Terminal System4–60 Rev. 0SDT5200 "TYPE"VER: X.X.XFUNCTION SELECTUTILITYUTILITYMODEM TYPEMODEM OPTIO
C5/K1/K3 Integrated Satellite Terminal System OperationRev. 0 4–61CARD # 3 SERIAL123456789Only if installedMODEM SERIAL #123456789Only if installedACC
Operation C5/K1/K3 Integrated Satellite Terminal System4–62 Rev. 04.1.3.11.5 Utility Modem Type FunctionsRefer to Figure 4-19.UTILITY Displays single
C5/K1/K3 Integrated Satellite Terminal System OperationRev. 0 4–63REV EMULATION Programs an emulation mode of a previous functional revision. This all
C5/K1/K3 Integrated Satellite Terminal System Table of ContentsRev. 0 xvTablesTable 1-1. Customer-Selectable Configured Units ...
Operation C5/K1/K3 Integrated Satellite Terminal System4–64 Rev. 0MODEM SERIAL # (Status Only.)Displays the modem serial number.CARD #1 SERIAL # (Stat
C5/K1/K3 Integrated Satellite Terminal System OperationRev. 0 4–65SDT5200 "TYPE"VER: X.X.XFUNCTION SELECTUTILITYUTILITYFACTORY SETUPUTILITY
Operation C5/K1/K3 Integrated Satellite Terminal System4–66 Rev. 0CUSTOMERDATAREMOTE SERIALINTERFACEFAULT INDICATORSIESS-308-2INTERFACEENCODER/MODULAT
C5/K1/K3 Integrated Satellite Terminal System OperationRev. 0 4–67CUSTOMERDATAREMOTE SERIALINTERFACEFAULT INDICATORSINASYNCTERFACEENCODER/MODULATORTRA
Operation C5/K1/K3 Integrated Satellite Terminal System4–68 Rev. 04.2 Software Configuration4.2.1 Modem TypesRefer to Figure 4-19.Refer to Table 4-1 f
C5/K1/K3 Integrated Satellite Terminal System OperationRev. 0 4–69Table 4-2. EFD Closed Network Parameter SettingsParameter Front Panel Setting Refer
Operation C5/K1/K3 Integrated Satellite Terminal System4–70 Rev. 04.2.1.3 ASYNC/AUPC OperationTo operate in the Asynchronous/AUPC configuration, the f
C5/K1/K3 Integrated Satellite Terminal System OperationRev. 0 4–71Asynchronous Overhead with AUPC is a closed network application that gives the usert
Operation C5/K1/K3 Integrated Satellite Terminal System4–72 Rev. 04.4.2 EIA-232, EIA-422, or V.35 Master/SlaveRefer to Figure 4-25 for:! Clocking blo
C5/K1/K3 Integrated Satellite Terminal System OperationRev. 0 4–73TXCLOCK = TX TERRESTRIALTXCLOCK = TX TERRESTRIALTRANSMITTRANSMITINTERNALOSCILLATORIN
Table of Contents C5/K1/K3 Integrated Satellite Terminal Systemxvi Rev. 0Table 3-10. Alarm Pinouts...
Operation C5/K1/K3 Integrated Satellite Terminal System4–74 Rev. 0TXCLOCK = TX TERRESTRIALSLAVETXCLOCK = TX TERRESTRIALTRANSMITTRANSMITINTERNALOSCILLA
C5/K1/K3 Integrated Satellite Terminal System OperationRev. 0 4–754.5 BufferingThe receive buffer serves two purposes:! Plesiochronous buffering of tw
Operation C5/K1/K3 Integrated Satellite Terminal System4–76 Rev. 0BIT 1BIT 2BIT 3BIT 4BIT 5BIT 6BIT 7BIT 1BIT 2BIT 3BIT 5BIT 6BIT 7ERRORINTERFACE1) IN
C5/K1/K3 Integrated Satellite Terminal System OperationRev. 0 4–77SATELLITEMOTIONANDORBITALINCLINATIONSATELLITENOMINALPOSITIONNSGEO-SYNCHRONOUSEQUATOR
Operation C5/K1/K3 Integrated Satellite Terminal System4–78 Rev. 04.5.1.1 DopplerA geostationary satellite should be positioned directly over the equa
C5/K1/K3 Integrated Satellite Terminal System OperationRev. 0 4–794.5.1.2 PlesiochronousThe stability of station reference clocks is normally 1 x 10-1
Operation C5/K1/K3 Integrated Satellite Terminal System4–80 Rev. 04.5.1.3 Frame/Multiframe LengthThe depth of the receive buffer required has been dis
C5/K1/K3 Integrated Satellite Terminal System OperationRev. 0 4–814.6 Initial DefaultsInitial default settings for the Satellite Terminal System are l
Operation C5/K1/K3 Integrated Satellite Terminal System4–82 Rev. 0Table 4-5. Initial Defaults (Continued)Function C5 K1 K3 C5 ASYNCInterface Configur
C5/K1/K3 Integrated Satellite Terminal System OperationRev. 0 4–83Table 4-5. Initial Defaults (Continued)Function C5 K1 K3 C5 ASYNCInterface UtilityT
Rev. 0 1–11Chapter 1. INTRODUCTIONThis chapter introduces the Integrated Satellite Terminal System. This system can beconfigured into three units:! C5
Operation C5/K1/K3 Integrated Satellite Terminal System4–84 Rev. 0This page is intentionally left blank.
Rev. 0 5-15-15Chapter 5. THEORY OF OPERATIONThis chapter defines the theory of operation data for the Satellite Terminal System,which includes:! Indoo
Theory of Operation C5/K1/K3 Integrated Satellite Terminal System5-2 Rev. 05.2 SDT-5200 Satellite Data Terminal5.2.1 Monitor and Control (M&C)Th
C5/K1/K3 Integrated Satellite Terminal System Theory of OperationRev. 0 5-3MODEM11 MHzCLOCKIC BUS2RAM ANDREALTIMECLOCKROM(M&C,BULK,BOOT)FAULTAND A
Theory of Operation C5/K1/K3 Integrated Satellite Terminal System5-4 Rev. 0The non-volatile RAM on the M&C module allows the module to retain conf
C5/K1/K3 Integrated Satellite Terminal System Theory of OperationRev. 0 5-55.2.3 Remote Baud RateThe remote communications baud rate and parity are p
Theory of Operation C5/K1/K3 Integrated Satellite Terminal System5-6 Rev. 05.3 ModulatorThe modulator provides PSK modulated carriers within the 780 t
C5/K1/K3 Integrated Satellite Terminal System Theory of OperationRev. 0 5-75.3.1 Modulator SpecificationsRefer to Chapter 2, Specifications.5.3.2 The
Theory of Operation C5/K1/K3 Integrated Satellite Terminal System5-8 Rev. 0The RF synthesizer is comprised of a Direct Digital Synthesis (DDS) chip; a
C5/K1/K3 Integrated Satellite Terminal System Theory of OperationRev. 0 5-95.3.3.1 BPSK EncodingThe modulator converts transmitted baseband data into
Introduction C5/K1/K3 Integrated Satellite Terminal System1–2 Rev. 0Figure 1-2. The Ku-Band (K1 or K3) SystemRefer to Table 1-1 for a matrix of custo
Theory of Operation C5/K1/K3 Integrated Satellite Terminal System5-10 Rev. 05.4 DemodulatorA block diagram of the demodulator is shown in Figure 5-3.T
C5/K1/K3 Integrated Satellite Terminal System Theory of OperationRev. 0 5-115.4.1 Demodulator SpecificationsRefer to Chapter 2, Specifications for dem
Theory of Operation C5/K1/K3 Integrated Satellite Terminal System5-12 Rev. 0The digital Costas loop, in conjunction with a Direct Digital Synthesizer
C5/K1/K3 Integrated Satellite Terminal System Theory of OperationRev. 0 5-135.5 DecoderThe IDU can be configured in any of the following forms:! Basic
Theory of Operation C5/K1/K3 Integrated Satellite Terminal System5-14 Rev. 0INTERFACEBASEBANDLOOPBACKTXOVERHEADTX TERRRECEIVERSLINEPOVERHEADOVERHEADRO
Rev. 0 6-16-16Chapter 6. SYSTEM CHECKOUTThis chapter provides the following information:! Satellite Terminal System Checkout! Fault Isolation! Module
System Checkout C5/K1/K3 Integrated Satellite Terminal SystemRev. 06-26.2 Interface CheckoutUse the following procedures and test setup in Figure 6-1
C5/K1/K3 Integrated Satellite Terminal System System CheckoutRev. 06-36.2.1 Modulator CheckoutUse the following procedure to check out the modulator:1
System Checkout C5/K1/K3 Integrated Satellite Terminal SystemRev. 06-4Table 6-1. Conversion to S/N and Eb/N0 Chart(dB) Code Rate 1/2 Code Rate 3/4 Co
C5/K1/K3 Integrated Satellite Terminal System System CheckoutRev. 06-5ATTEN 10 dB2.00 dB/DIVRES BANDWIDTH10.0 kHzRL -49.00 dBmCENTER 70.000 MHz*RB10.0
C5/K1/K3 Integrated Satellite Terminal System IntroductionRev. 0 1–3MODEM/IDUUP.M & CHPADOWNCONVERTERCONVERTERREREJECTFILTEROMTTXREJECTFILTERLNAFE
System Checkout C5/K1/K3 Integrated Satellite Terminal SystemRev. 06-66.2.2 Demodulator CheckoutUse the following procedure to test the demodulator.1.
C5/K1/K3 Integrated Satellite Terminal System System CheckoutRev. 06-7Note the inversion ofOUT1 and OUT2 withrespect to IN1 and IN2due to the 'HI
System Checkout C5/K1/K3 Integrated Satellite Terminal SystemRev. 06-8WITH NOISEWITHOUT NOISEFigure 6-5. Typical Eye Constellations
C5/K1/K3 Integrated Satellite Terminal System System CheckoutRev. 06-96.3 Fault IsolationThe IDU design allows a technician to repair a faulty modem o
System Checkout C5/K1/K3 Integrated Satellite Terminal SystemRev. 06-10Table 6-2. Fault TreeTRANSMITTER FAULTSTXIFOUTPUTOFFTXFAULTLEDTXFAULTRELAYRXFA
C5/K1/K3 Integrated Satellite Terminal System System CheckoutRev. 06-11Table 6-2. Fault Tree (Continued)TX INTERFACE FAULTSTXIFOUTPUTOFFTXFAULTLEDTXF
System Checkout C5/K1/K3 Integrated Satellite Terminal SystemRev. 06-12Table 6-2. Fault Tree (Continued)COMMON EQUIP FAULTSTXIFOUTPUTOFFTXFAULTLEDTXF
C5/K1/K3 Integrated Satellite Terminal System System CheckoutRev. 06-136.3.2 Faults/Alarms DisplayGeneral fault, status, and alarm information are ind
System Checkout C5/K1/K3 Integrated Satellite Terminal SystemRev. 06-146.3.3.1 Transmitter FaultsFault/Alarm Possible Problem and ActionIF SYNTHESIZER
C5/K1/K3 Integrated Satellite Terminal System System CheckoutRev. 06-156.3.3.2 Receiver FaultsFault/Alarm Possible Problem and ActionCARRIER DETECT Ca
Introduction C5/K1/K3 Integrated Satellite Terminal System1–4 Rev. 01.1.1 DescriptionThe SDT-5200 indoor unit (IDU) is a 1 RU rack-mounted module that
System Checkout C5/K1/K3 Integrated Satellite Terminal SystemRev. 06-166.3.3.3 Transmit Interface FaultsFault/Alarm Possible Problem and ActionTX DAT
C5/K1/K3 Integrated Satellite Terminal System System CheckoutRev. 06-176.3.3.4 Receive Interface FaultsFault/Alarm Possible Problem and ActionBUFFER
System Checkout C5/K1/K3 Integrated Satellite Terminal SystemRev. 06-18Fault/Alarm Possible Problem and ActionBUFFER CLKPLLBuffer clock phase-locked l
C5/K1/K3 Integrated Satellite Terminal System System CheckoutRev. 06-196.3.3.5 Common Equipment FaultsFault/Alarm Possible Problem and ActionBATTERY/
System Checkout C5/K1/K3 Integrated Satellite Terminal SystemRev. 06-20This page is intentionally left blank.
Rev. 0 A–1AAAppendix A. OPTIONSThis appendix describes the options available for the Satellite Terminal System. Availableoptions are:! Fully Accessibl
Options C5/K1/K3 Integrated Satellite Terminal SystemA–2 Rev. 0Other options are available through conventional changes such as installing daughter ca
C5/K1/K3 Integrated Satellite Terminal System OptionsRev. 0 A–3A.1.2.1 Activation Procedure1. Obtain IDU serial number as follows:a. Press [CLEAR] to
Options C5/K1/K3 Integrated Satellite Terminal SystemA–4 Rev. 0h. Record Card #2 serial number, if displayed: i. Press [CLE
C5/K1/K3 Integrated Satellite Terminal System OptionsRev. 0 A–57. Check upgrade as follows:a. Press [CLEAR] to return to the Main menu.b. Use ["]
C5/K1/K3 Integrated Satellite Terminal System IntroductionRev. 0 1–5The Ku-Band satellite terminal system is divided into two areas of operation:1. SD
Options C5/K1/K3 Integrated Satellite Terminal SystemA–6 Rev. 0A.2 Interface OptionsA.2.1 Asynchronous Interface/AUPCThe asynchronous (ASYNC) interfac
C5/K1/K3 Integrated Satellite Terminal System OptionsRev. 0 A–7The ASYNC interface PCB also provides its own Doppler buffer, which has a maximumdepth
Options C5/K1/K3 Integrated Satellite Terminal SystemA–8 Rev. 0A.2.1.1 Local AUPCThe AUPC function allows each of two modems in a closed link to contr
C5/K1/K3 Integrated Satellite Terminal System OptionsRev. 0 A–9A.2.1.1.1 Self-Monitoring Local Modem AUPC ControlNote: This feature is available with
Options C5/K1/K3 Integrated Satellite Terminal SystemA–10 Rev. 0A.2.1.2 Remote AUPCThis feature allows the user to monitor and control a remote modem
C5/K1/K3 Integrated Satellite Terminal System OptionsRev. 0 A–11A.2.1.3.3 Multiplexer OperationThe multiplexer receives terrestrial and ASYNC data fro
Options C5/K1/K3 Integrated Satellite Terminal SystemA–12 Rev. 0The Doppler buffer receives data clocked by the overhead clock from the demodulatorand
C5/K1/K3 Integrated Satellite Terminal System OptionsRev. 0 A–13A.2.1.3.8 Non-ASYNC OperationThe ASYNC interface has pass-through capability. If ASYNC
Options C5/K1/K3 Integrated Satellite Terminal SystemA–14 Rev. 0The following table lists examples.If DR = 8.000K Baud rate can be 150 or lowerIf DR =
C5/K1/K3 Integrated Satellite Terminal System OptionsRev. 0 A–15Before remote ASYNC communications can be implemented, the following must occur:! At b
Introduction C5/K1/K3 Integrated Satellite Terminal System1–6 Rev. 01.2 Modem Feature Upgrade (FAST)The SDT-5200 indoor unit (IDU) has a variety of o
Options C5/K1/K3 Integrated Satellite Terminal SystemA–16 Rev. 0WYSEREMOTE TERMINAL(OR EQUIVALENT)ASYNC INTERFACE ASYNC INTERFACEJ8J6TX -30 dBm RXRX T
C5/K1/K3 Integrated Satellite Terminal System OptionsRev. 0 A–17A.2.1.5.1 Configuration #1 (Local EIA-232 to Remote EIA-232)Table A-3. Local EIA-232
Options C5/K1/K3 Integrated Satellite Terminal SystemA–18 Rev. 0A.2.1.5.2 Configuration #2 (Local EIA-232 to Remote EIA-485 [2-Wire])Table A-4. Loca
C5/K1/K3 Integrated Satellite Terminal System OptionsRev. 0 A–19A.2.1.5.3 Configuration #3 (Local EIA-485 [2-Wire] to Remote EIA-232)Table A-5. Loca
Options C5/K1/K3 Integrated Satellite Terminal SystemA–20 Rev. 0The local end cable connects the 25-pin female ASYNC connector (on either thebreakout
C5/K1/K3 Integrated Satellite Terminal System OptionsRev. 0 A–21A.2.1.6 ASYNC/AUPC Modem DefaultsRefer to Table A-6 for ASYNC/AUPC modem defaults.Tab
Options C5/K1/K3 Integrated Satellite Terminal SystemA–22 Rev. 0A.2.2 DecoderA.2.2.1 Sequential DecoderThe sequential decoder is used in closed networ
C5/K1/K3 Integrated Satellite Terminal System OptionsRev. 0 A–23A.2.2.1.1 Theory of OperationThe sequential decoder also works in conjunction with th
Options C5/K1/K3 Integrated Satellite Terminal SystemA–24 Rev. 0The corrected data is buffered through the output RAM and re-timing circuit, whichprov
C5/K1/K3 Integrated Satellite Terminal System OptionsRev. 0 A–25A.2.2.2.1 SpecificationsRefer to Table A-7 for Viterbi specification.Table A-7. Viter
C5/K1/K3 Integrated Satellite Terminal System IntroductionRev. 0 1–71.3 Modes of OperationThe ASYNC/AUPC option allows an additional overhead channel
Options C5/K1/K3 Integrated Satellite Terminal SystemA–26 Rev. 0The branch metrics are then processed by the ASC computer. The ASC computer makesdecis
C5/K1/K3 Integrated Satellite Terminal System OptionsRev. 0 A–27A.2.3 Asymmetrical Loop TimingAsymmetrical Loop Timing is the same timing method that
Options C5/K1/K3 Integrated Satellite Terminal SystemA–28 Rev. 0PLLDDSTXDTXCEXTREFINTRXCS2S1MCSTTTTXDS4S3OUTPUTClock Selection S1 set to: S2 set to: S
C5/K1/K3 Integrated Satellite Terminal System OptionsRev. 0 A–29BUFPLLSATINTRXDMCEXTTERRTTRTDDSEXTREFINTRXDRXCNote: PLL will be bypassed when the rece
Options C5/K1/K3 Integrated Satellite Terminal SystemA–30 Rev. 0Master Site Option No. 2:1. Set Configuration/Modulator/Modem Reference to INTERNAL.2.
C5/K1/K3 Integrated Satellite Terminal System OptionsRev. 0 A–31A.3 Reed-Solomon OptionA.3.1 Reed-Solomon CodecThe modem must have the Reed-Solomon PC
Options C5/K1/K3 Integrated Satellite Terminal SystemA–32 Rev. 0The Reed-Solomon Codec works in conjunction with the Viterbi decoder and includesaddit
C5/K1/K3 Integrated Satellite Terminal System OptionsRev. 0 A–33A.3.1.2 Theory of OperationThe Reed-Solomon Codec works in conjunction with the inter
Options C5/K1/K3 Integrated Satellite Terminal SystemA–34 Rev. 0The data and clock signals (MUXDATA and MUXCLK) come from the multiplexer onthe main P
C5/K1/K3 Integrated Satellite Terminal System OptionsRev. 0 A–35kBYTESOF DATA'RSWORD'nBYTES1RSWORD1RSPAGERS SYNCHPERIODUNIQUE WORD BYTESGO I
Introduction C5/K1/K3 Integrated Satellite Terminal System1–8 Rev. 01.4 Component DescriptionThe C-Band (Figure 1-3) is divided into three distinct ar
Options C5/K1/K3 Integrated Satellite Terminal SystemA–36 Rev. 0A.3.1.4 Reed-Solomon DecoderRefer to Figure A-12 for a block diagram of the Reed-Solom
C5/K1/K3 Integrated Satellite Terminal System OptionsRev. 0 A–37Refer to Figure A-11 for the Reed-Solomon code page format. The outer Codec reads thed
Options C5/K1/K3 Integrated Satellite Terminal SystemA–38 Rev. 0A.3.1.6 UnpackingCAUTIONThis equipment contains parts and assemblies sensitive to dama
C5/K1/K3 Integrated Satellite Terminal System OptionsRev. 0 A–39CBAFigure A-13. Reed-Solomon Codec Installation
Options C5/K1/K3 Integrated Satellite Terminal SystemA–40 Rev. 0This page is intentionally left blank.
Rev. 0 B–1BAppendix B. REMOTE CONTROL OPERATIONThis appendix describes the remote control operation of the C5 Satellite Terminal System.! Firmware num
Remote Control Operation C5/K1/K3 Integrated Satellite Terminal SystemB–2 Rev. 0Messages on the remote link fall into the categories of commands and r
C5/K1/K3 Integrated Satellite Terminal System Remote Control OperationRev. 0 B–3B.2.3 Faults MonitoredFaults monitored by the terminal and the action
Remote Control Operation C5/K1/K3 Integrated Satellite Terminal SystemB–4 Rev. 0B.2.6 Command/ResponseThe command/response portion of the message cont
C5/K1/K3 Integrated Satellite Terminal System Remote Control OperationRev. 0 B–5B.3 Configuration Commands/ResponsesB.3.1 ModulatorModulatorFrequency
C5/K1/K3 Integrated Satellite Terminal System IntroductionRev. 0 1–91.4.1 SDT-5200 Indoor UnitThe SDT-5200 Indoor unit (Figure 1-5), here after refer
Remote Control Operation C5/K1/K3 Integrated Satellite Terminal SystemB–6 Rev. 0SetModulatorOutputPower LevelCommand:Response:Status:<add/MOP_snn.n
C5/K1/K3 Integrated Satellite Terminal System Remote Control OperationRev. 0 B–7B.3.2 DemodulatorDemodulatorBandCommand:Response:Status:Response:<a
Remote Control Operation C5/K1/K3 Integrated Satellite Terminal SystemB–8 Rev. 0IF Loopback Command:Response:Status:Response:<add/IFL_xxx'cr&a
C5/K1/K3 Integrated Satellite Terminal System Remote Control OperationRev. 0 B–9B.3.3 InterfaceInterfaceTransmitOverhead TypeCommand:Response:Status:R
Remote Control Operation C5/K1/K3 Integrated Satellite Terminal SystemB–10 Rev. 0Interface Loop-backCommand:Response:Status:Response:<add/ILB_xxx&a
C5/K1/K3 Integrated Satellite Terminal System Remote Control OperationRev. 0 B–11Interface CodingFormat TransmitCommand:Response:Status:Response:<a
Remote Control Operation C5/K1/K3 Integrated Satellite Terminal SystemB–12 Rev. 0ASYNC ReceiveOverheadChannel Parity(RX ASYNCOverhead only)Command:Res
C5/K1/K3 Integrated Satellite Terminal System Remote Control OperationRev. 0 B–13B.4 SystemTime Of Day Command:Response:Status:Response:<add/TIME_h
Remote Control Operation C5/K1/K3 Integrated Satellite Terminal SystemB–14 Rev. 0RTS TX-IFControl ModeCommand:Response:Status:Response:<add/RTSM_xx
C5/K1/K3 Integrated Satellite Terminal System Remote Control OperationRev. 0 B–15B.5 Automatic Uplink Power Control (AUPC) ConfigurationCommandsAUPC
Copyright © Comtech EFData, 2000.All rights reserved.Printed in the USA.Comtech EFData, 2114 West 7th Place, Tempe, Arizona 85281 USA, (480) 333-2200,
Introduction C5/K1/K3 Integrated Satellite Terminal System1–10 Rev. 01.4.2 C-Band Outdoor Unit (ODU)The ODU (Figure 1-6) consists of the following as
Remote Control Operation C5/K1/K3 Integrated Satellite Terminal SystemB–16 Rev. 0AUPC LocalCarrier LossAction(ASYNCOverheadonly)Command:Response:Statu
C5/K1/K3 Integrated Satellite Terminal System Remote Control OperationRev. 0 B–17B.6 Status Commands/ResponsesModulatorConfigurationStatusCommand:Resp
Remote Control Operation C5/K1/K3 Integrated Satellite Terminal SystemB–18 Rev. 0MINP_snn.n'cr' (Note 1)MAXP_snn.n'cr' (Note 1)LCL
C5/K1/K3 Integrated Satellite Terminal System Remote Control OperationRev. 0 B–19Demodulator/DecoderConfigurationProgramStatusCommand:Response:<add
Remote Control Operation C5/K1/K3 Integrated Satellite Terminal SystemB–20 Rev. 0InterfaceConfigurationStatusCommand:Response:<add/ICS_'cr&apo
C5/K1/K3 Integrated Satellite Terminal System Remote Control OperationRev. 0 B–21MODEMFaults Status(Summary)Command:Response:<add/MFS_'cr&apos
Remote Control Operation C5/K1/K3 Integrated Satellite Terminal SystemB–22 Rev. 0Outdoor UnitStatusCommand:Response:<add/OUS_'cr'>add/
C5/K1/K3 Integrated Satellite Terminal System Remote Control OperationRev. 0 B–23InterfaceRead ErrorStatusCommand:Response:<add/IRES_'cr'
Remote Control Operation C5/K1/K3 Integrated Satellite Terminal SystemB–24 Rev. 0ReceiveSignal LevelStatusCommand:Response:<add/RSL_'cr'&
C5/K1/K3 Integrated Satellite Terminal System Remote Control OperationRev. 0 B–25B.7 Stored FaultsInformation on stored faults is returned when reques
C5/K1/K3 Integrated Satellite Terminal System IntroductionRev. 0 1–111.4.3 Ku-Band Outdoor Unit (ODU)The Ku-Band ODU (K1 or K3) is a weatherproof, en
Remote Control Operation C5/K1/K3 Integrated Satellite Terminal SystemB–26 Rev. 0CommonEquipmentStored FaultsCommand:Response:<add/CSF_#'cr&ap
C5/K1/K3 Integrated Satellite Terminal System Remote Control OperationRev. 0 B–27BulkConsol.AnalogStatusCommand:Response:<add/BCAS_'cr'&g
Remote Control Operation C5/K1/K3 Integrated Satellite Terminal SystemB–28 Rev. 0BulkConsol.StatusCommand:Response:<add/BCS_'cr'>add/B
C5/K1/K3 Integrated Satellite Terminal System Remote Control OperationRev. 0 B–29BulkConsol.Status(continued)ParameterNumberParameter Name(Command Ref
Remote Control Operation C5/K1/K3 Integrated Satellite Terminal SystemB–30 Rev. 0BulkConsol.Status(continued)ParameterNumberParameter Name(Command Ref
C5/K1/K3 Integrated Satellite Terminal System Remote Control OperationRev. 0 B–31BulkConsol.Status(continued)ParameterNumberParameter Name(Command Ref
Remote Control Operation C5/K1/K3 Integrated Satellite Terminal SystemB–32 Rev. 0BulkConsol.Status(continued)ParameterNumberParameter Name(Command Ref
C5/K1/K3 Integrated Satellite Terminal System Remote Control OperationRev. 0 B–33BulkConsol.Status(continued)ParameterNumberParameter Name(Command Ref
Remote Control Operation C5/K1/K3 Integrated Satellite Terminal SystemB–34 Rev. 0BulkConsol.Status(continued)ParameterNumberParameter Name(Command Ref
C5/K1/K3 Integrated Satellite Terminal System Remote Control OperationRev. 0 B–35BulkConsol.StatusFaultsCommand:Response:<add/BCSF_'cr'&g
Introduction C5/K1/K3 Integrated Satellite Terminal System1–12 Rev. 01.4.4 Low-Noise Phase-Locked Amplifier (LNA)Note: This component is used in the
Remote Control Operation C5/K1/K3 Integrated Satellite Terminal SystemB–36 Rev. 0Character 'h': Interface transmit side faults character 2.B
C5/K1/K3 Integrated Satellite Terminal System Remote Control OperationRev. 0 B–37Character 'p': Interface backward alarm status character 1.
Remote Control Operation C5/K1/K3 Integrated Satellite Terminal SystemB–38 Rev. 0ChangeStatusCommand:Response:<add/CS_'cr'>add/CS_x&ap
C5/K1/K3 Integrated Satellite Terminal System Remote Control OperationRev. 0 B–39ModemOptions/Misc.InformationCommand:Response:<add/MOI_'cr&ap
Remote Control Operation C5/K1/K3 Integrated Satellite Terminal SystemB–40 Rev. 0Built In SelfTestCommand:Response:Response:Status:Response:<add/BI
Rev. 0 g–1GGlossary The following is a list of acronyms and abbreviations that may be found in this manual.Acronym/Abbreviation Definition!OhmsAAmpere
Glossary C5/K1/K3 Integrated Satellite Terminal Systemg–2 Rev. 0Acronym/Abbreviation DefinitionCS Clear to SendCSC Comstream CompatibleCTS Clear to Se
C5/K1/K3 Integrated Satellite Terminal System GlossaryRev. 0 g–3Acronym/Abbreviation DefinitionM&C or MC Monitor and ControlmA MilliamperesMax Max
Glossary C5/K1/K3 Integrated Satellite Terminal Systemg–4 Rev. 0Acronym/Abbreviation DefinitionUART Universal Asynchronous Receiver/TransmitterUNAVAL
Rev. 0 i–1IIndex Acquisition Time, 3–30Activation Procedure, A–3Additional Features, 1–5, A–3Alarm (J10), 2–36Asymmetrical Loop Timing, 1–5, 2–37, 3–2
C5/K1/K3 Integrated Satellite Terminal System IntroductionRev. 0 1–131.5 OptionsThe following options (Table 1-5 )are applicable to the Ku-Band config
Index C5/K1/K3 Integrated Satellite Terminal Systemi–2 Rev. 0Demodulator IF Input Shape, 4–35Demodulator Specifications, 2–12, 2–25, 5-11Demultiplexer
C5/K1/K3 Integrated Satellite Terminal System IndexRev. 0 i–3Reed-Solomon Encoder, 2–48, A–26, A–36, B–8, B–18,B–19, B–32Reed-Solomon Specifications (
Index C5/K1/K3 Integrated Satellite Terminal Systemi–4 Rev. 0This page is intentionally left blank.
Introduction C5/K1/K3 Integrated Satellite Terminal System1–14 Rev. 0This page is intentionally left blank.
Rev. 0 2–12Chapter 2 SPECIFICATIONSThe chapter provides the necessary specifications for the Satellite Terminal System.2.1 C-Band System Specification
Specifications C5/K1/K3 Integrated Satellite Terminal System2–2 Rev. 0Table 2-1. C-Band System Specifications (Continued)Parameter SpecificationsData
C5/K1/K3 Integrated Satellite Terminal System SpecificationsRev. 0 2–32.1.1 C-Band Receive SpecificationsRefer to Table 2-2 for receive specifications
Specifications C5/K1/K3 Integrated Satellite Terminal System2–4 Rev. 02.1.2 C-Band Transmit SpecificationsRefer to Table 2-3 for transmit specificati
C5/K1/K3 Integrated Satellite Terminal System SpecificationsRev. 0 2–52.1.3 C-Band Transmit Reject Filter SpecificationsRefer to Table 2-4 for transm
Warranty PolicyThe product, manufactured by EFData, is warranted against defects in material andworkmanship for a period of one year from the date of
Specifications C5/K1/K3 Integrated Satellite Terminal System2–6 Rev. 02.1.4.2 Modulation and Encoding TypesRefer to Table 2-6 for combinations of mod
C5/K1/K3 Integrated Satellite Terminal System SpecificationsRev. 0 2–72.1.5 C-Band Transmit (TX)2.1.5.1 Transmit FrequencyThe operator can select the
Specifications C5/K1/K3 Integrated Satellite Terminal System2–8 Rev. 02.1.5.5 Transmit Power( The transmit power is operator-selectable from +25 to +3
C5/K1/K3 Integrated Satellite Terminal System SpecificationsRev. 0 2–92.1.6 C-Band Transmit Test ModesThe following transmit test modes are available
Specifications C5/K1/K3 Integrated Satellite Terminal System2–10 Rev. 02.1.10 C-Band Demodulator-Related Specifications2.1.10.1 Digital Data RateThe
C5/K1/K3 Integrated Satellite Terminal System SpecificationsRev. 0 2–112.1.10.2 Demodulation and FEC Decoding TypesRefer to Table 2-9 for combination
Specifications C5/K1/K3 Integrated Satellite Terminal System2–12 Rev. 02.1.10.4 Deinterleaver (Reed-Solomon Codec)Depth 8 (Closed Network).Note: The
C5/K1/K3 Integrated Satellite Terminal System SpecificationsRev. 0 2–132.1.10.8 Channel Spacing/Adjacent Carrier PerformanceThe terminal bit error pe
Specifications C5/K1/K3 Integrated Satellite Terminal System2–14 Rev. 0This page is intentionally left blank.
C5/K1/K3 Integrated Satellite Terminal System SpecificationsRev. 0 2–152.2 Ku-Band System SpecificationsRefer to Table 2-10 for system specifications.
Rev. 0 iPrefaceAbout this ManualThis manual provides installation and operation information for the EFData C-Band orKu-Band Integrated Satellite Termi
Specifications C5/K1/K3 Integrated Satellite Terminal System2–16 Rev. 02.2.1 Ku-Band Transmit SpecificationsRefer to Table 2-11 for Ku-Band transmit s
C5/K1/K3 Integrated Satellite Terminal System SpecificationsRev. 0 2–172.2.2 Ku-Band Receiver SpecificationsRefer to Table 2-12 for Ku-Band receiver s
Specifications C5/K1/K3 Integrated Satellite Terminal System2–18 Rev. 02.2.3 Ku-Band Modulator-Related Specifications2.2.3.1 Digital Data RateThe di
C5/K1/K3 Integrated Satellite Terminal System SpecificationsRev. 0 2–192.2.3.2 Modulation and Encoding TypesRefer to Table 2-14 for combinations of m
Specifications C5/K1/K3 Integrated Satellite Terminal System2–20 Rev. 02.2.3.4 Interleaver (Reed-Solomon Codec)Depth 8 (Closed Network, ASYNC).Note:
C5/K1/K3 Integrated Satellite Terminal System SpecificationsRev. 0 2–212.2.4.5 Transmit IF Power1. The transmit power is operator-selectable from +17
Specifications C5/K1/K3 Integrated Satellite Terminal System2–22 Rev. 02.2.4.8 Transmit Test ModesThe following transmit test modes are available to
C5/K1/K3 Integrated Satellite Terminal System SpecificationsRev. 0 2–232.2.5 Ku-Band Receive (RX) Specifications2.2.5.1 Digital Data RateThe digital
Specifications C5/K1/K3 Integrated Satellite Terminal System2–24 Rev. 02.2.5.2 Demodulation and FEC Decoding TypesRefer to Table 2-16 for combination
C5/K1/K3 Integrated Satellite Terminal System SpecificationsRev. 0 2–252.2.5.4 Deinterleaver (Reed-Solomon Codec)Depth 8 (Closed Network).Note: The R
Preface C5/K1/K3 Integrated Satellite Terminal Systemii Rev. 0EMC DirectiveDirective: EN55022This equipment meets EN55022.This is a Class A product. I
Specifications C5/K1/K3 Integrated Satellite Terminal System2–26 Rev. 02.2.5.8 Channel Spacing/Adjacent Carrier PerformanceThe terminal bit error per
C5/K1/K3 Integrated Satellite Terminal System SpecificationsRev. 0 2–272.3 Bit Error Rate PerformanceNote: The following BER performance data applies
Specifications C5/K1/K3 Integrated Satellite Terminal System2–28 Rev. 02.3.1 Performance with Noise and Viterbi DecoderRefer to Table 2-18 for noise
C5/K1/K3 Integrated Satellite Terminal System SpecificationsRev. 0 2–29Figure 2-1. Performance with Noise and Viterbi Decoder10-410-310-510-6BER10-71
Specifications C5/K1/K3 Integrated Satellite Terminal System2–30 Rev. 02.3.2 Performance with Noise, Viterbi Decoder, and Reed-Solomon(Optional)Refer
C5/K1/K3 Integrated Satellite Terminal System SpecificationsRev. 0 2–31Figure 2-2. Performance with Noise, Viterbi Decoder, and Reed-Solomon10-410-31
Specifications C5/K1/K3 Integrated Satellite Terminal System2–32 Rev. 02.3.3 Performance with Noise, 56 kbit/s, and Sequential Decoder(Optional)Refer
C5/K1/K3 Integrated Satellite Terminal System SpecificationsRev. 0 2–33Figure 2-3. Performance with Noise, 56 kbit/s, and Sequential Decoder10101010B
Specifications C5/K1/K3 Integrated Satellite Terminal System2–34 Rev. 02.3.4 Performance with Noise, 1544 kbit/s, and Sequential DecoderRefer to Tabl
C5/K1/K3 Integrated Satellite Terminal System SpecificationsRev. 0 2–35Figure 2-4. Performance with Noise, 1544 kbit/s, and Sequential Decoder10-410-
C5/K1/K3 Integrated Satellite Terminal System PrefaceRev. 0 iiiInternational Symbols:Alternating Current.Fuse.Notes:1. For additional symbols, refer t
Specifications C5/K1/K3 Integrated Satellite Terminal System2–36 Rev. 02.4 Acquisition TimesRefer to Table 2-22 for acquisition times.Table 2-22. Acq
C5/K1/K3 Integrated Satellite Terminal System SpecificationsRev. 0 2–372.4.3 APS Output (ODU)The Antenna Pointing System (APS) output on the ODU has
Specifications C5/K1/K3 Integrated Satellite Terminal System2–38 Rev. 02.5 Interface Specifications2.5.1 Clock2.5.1.1 Transmit Clock SourceThe transm
C5/K1/K3 Integrated Satellite Terminal System SpecificationsRev. 0 2–392.5.1.3 Transmit Clock Switching Due to Failure of Selected ClockThe terminal
Specifications C5/K1/K3 Integrated Satellite Terminal System2–40 Rev. 02.5.1.8 Receive Clock Phase AdjustmentThe receive clock phase can be set by th
C5/K1/K3 Integrated Satellite Terminal System SpecificationsRev. 0 2–412.5.1.13 Loopback ModesThe operator can select one of the following interface l
Specifications C5/K1/K3 Integrated Satellite Terminal System2–42 Rev. 02.5.2.2 EIA-232 SpecificationRefer to Table 2-23 for EIA-232 specifications.Tab
C5/K1/K3 Integrated Satellite Terminal System SpecificationsRev. 0 2–432.5.2.3 V.35 Specification V.10, V.11 Specification, Circuit SupportedRefer to
Specifications C5/K1/K3 Integrated Satellite Terminal System2–44 Rev. 02.5.2.4 EIA-449/EIA-422 SpecificationsRefer to Table 2-25 for EIA-449/EIA-422 s
C5/K1/K3 Integrated Satellite Terminal System SpecificationsRev. 0 2–452.5.3 Asynchronous Overhead Specification (Optional)The operator can select EI
Preface C5/K1/K3 Integrated Satellite Terminal Systemiv Rev. 0Customer SupportContact the EFData Customer Support Department for:! Product support! In
Specifications C5/K1/K3 Integrated Satellite Terminal System2–46 Rev. 02.5.3.1 Local Automatic Uplink Power Control (AUPC)AUPC functions are availabl
C5/K1/K3 Integrated Satellite Terminal System SpecificationsRev. 0 2–472.6 System Specifications2.6.1 Test ModesRefer to Table 2-27 for available test
Specifications C5/K1/K3 Integrated Satellite Terminal System2–48 Rev. 02.6.2 Remote ControlAll terminal functions are controlled remotely through the
C5/K1/K3 Integrated Satellite Terminal System SpecificationsRev. 0 2–49Table 2-29. Remote Control Functions (Continued)Interface (Continued)Receive D
Specifications C5/K1/K3 Integrated Satellite Terminal System2–50 Rev. 02.7 Component Specifications2.7.1 OptionsRefer to Table 2-29 for options.Table
C5/K1/K3 Integrated Satellite Terminal System SpecificationsRev. 0 2–512.7.2 SDT-5200 (IDU) System SpecificationsThe SDT-5200 IDU is a complete, vari
Specifications C5/K1/K3 Integrated Satellite Terminal System2–52 Rev. 02.7.2.1 IDU Transmit SpecificationRefer to Table 2-31 for IDU transmit specific
C5/K1/K3 Integrated Satellite Terminal System SpecificationsRev. 0 2–532.7.2.2 IDU Receive SpecificationRefer to Table 2-32 for IDU receive specificat
Specifications C5/K1/K3 Integrated Satellite Terminal System2–54 Rev. 02.7.3 C-Band Outdoor UnitThe C-Band ODU is mounted on the feed support arm of a
C5/K1/K3 Integrated Satellite Terminal System SpecificationsRev. 0 2–55Table 2-34. C-Band ODU Specifications (Continued)Parameter SpecificationsEnvir
Rev. 0 vTable of ContentsCHAPTER 1. INTRODUCTION...1–11.1 Overview...
Specifications C5/K1/K3 Integrated Satellite Terminal System2–56 Rev. 02.7.4 Ku-Band Outdoor UnitThe ODU accepts a 790 % 11 MHz TX IF signal, and tran
C5/K1/K3 Integrated Satellite Terminal System SpecificationsRev. 0 2–57Table 2-35. Ku-Band ODU Specifications (Continued)Parameter SpecificationsEnvi
Specifications C5/K1/K3 Integrated Satellite Terminal System2–58 Rev. 02.7.5 C-Band LNA SpecificationsRefer to Table 2-35 for C-Band LNA specificatio
C5/K1/K3 Integrated Satellite Terminal System SpecificationsRev. 0 2–59This page is intentionally left blank.
Specifications C5/K1/K3 Integrated Satellite Terminal System2–60 Rev. 02.8 Dimensional Envelopes2.8.1 SDT-5200 Dimensional EnvelopeRefer to Figure 2-
C5/K1/K3 Integrated Satellite Terminal System SpecificationsRev. 0 2–612.8.2 C-Band Outdoor Unit (ODU) Dimensional EnvelopeRefer to Figure 2-6 for C-
Specifications C5/K1/K3 Integrated Satellite Terminal System2–62 Rev. 02.8.3 Ku-Band Outdoor Unit Dimensional EnvelopeRefer to Figure 2-7 for Ku-Band
Rev. 0 3–13Chapter 3. INSTALLATIONThis chapter provides installation and mounting instructions for the Satellite TerminalSystem.3.1 UnpackingThe Satel
Installation C5/K1/K3 Integrated Satellite Terminal System3–2 Rev. 03.2 Equipment Inspection3.2.1 Included PartsA typical Satellite Terminal System co
C5/K1/K3 Integrated Satellite Terminal System InstallationRev. 0 3–33.2.1.1 Cable Assembly (Customer-Furnished)CAUTIONEFData recommends the use of a